294
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amcproc.fb
Chapter 9, 264 Using the Analog Call Processing Subsystem
Using the CALL CONTROL Screen to test AMPS Authentication
d
SID
- Enter the system identification number of the Test Set as a
decimal number.
e
Chan:
(right-hand field) - Enter the
voice channel number which will be
assigned to the mobile station by the Test Set as either an initial voice
channel assignment or as a handoff voice channel assignment.
f
Pwr Lvl:
(right-hand field) - Enter
the Voice Mobile Attenuation Code
(VMAC). The VMAC determines the mobile station power level to be used
on the voice channel.
g
SAT:
(right-hand field) - Enter
the SAT frequency to be used on the
designated voice-channel.
3. Select
CALL CNFG
under the
To Screen
menu. The CALL CONFIGURATION
screen will be displayed.
4. Verify that the Test Set’s configuration information is appropriate for the mobile station
to be tested. Check the following field:
a
CMAX
- Set the number of access channels in the system. This will
determine how many channels must be scanned by the mobile station
when trying to access the Test Set. The value of this field will affect
the time required for the mobile station to connect with the Test Set.
Turn on the Test Set’s Control Channel
1. If not already done, condition the Test Set.
See "Conditioning the Test Set for Call
for further information.
2. If not already done, configure the Test Set.
See "Configure the Test Set" on page 286
for further information.
3. If the CALL CONTROL screen is not displayed, select
CALL CNTL
from the
To
Screen
menu. The CALL CONTROL screen will be displayed.
4. Select
Active
field. The
Active
annunciator will light when the control channel is
turned on.
Initialize Call Processing with Authentication
There are two methods to initialize Call Processing with authentication.
•
Initializing Call Processing with Authentication
with the Test Set.
•
Initializing Call Processing with Authentication
with the Test Set.
Initialize Call
Processing through
Registration
1. Ensure that the Test Set is in the active state.
See "Turn On The Test Set’s Control
1. for information on how to activate the Test Set.
2. Connect the mobile station to the Test Set as shown in
figure 2, "Connecting a Mobile
Station to the Test Set," on page 269
.
3. Turn on the mobile station.
4. If the CALL CONTROL screen is not displayed, select
CALL CNTL
under the
To
Screen
menu. The CALL CONTROL screen will be displayed.
5. Position the cursor on the
Display
field and select
Data
.
Содержание HP 8924C
Страница 21: ...Contents 21 N mkt MANUALS HP8924C APPMOD BOOK APPMOD TOC Table of Contents Index 351 ...
Страница 22: ...Contents 22 N mkt MANUALS HP8924C APPMOD BOOK APPMOD TOC ...
Страница 51: ...51 N mkt MANUALS HP8924C APPMOD BOOK chapters amcall fb Chapter 2 Setting Up a Call 2 Setting Up a Call ...
Страница 71: ...71 N mkt MANUALS HP8924C APPMOD BOOK chapters amrcvrt fb Chapter 3 CDMA Receiver Tests 3 CDMA Receiver Tests ...