175
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amtxtst.fb
Chapter 4, CDMA Transmitter Tests
Measuring the Range of Open Loop Output Power
Cha
p
te
r 4
CDM
A T
ra
n
s
m
itte
r
Te
s
ts
Measuring the Range of Open Loop Output Power
The Test Set measures the range over which the mobile-station-under-test
(MSUT) can adjust its Effective Radiated Power (ERP) in response to the power
level it receives from the Test Set. This test is performed according to TIA IS-98
standards, except that
Îor
is set to
−
35 dBm/BW instead of the recommended
value of
−
25 dBm/BW for the first test.
Test Prerequisites
•
The Channel Power measurement should be calibrated at least as often as the following
conditions arise:
•
5 °C change in operating temperature
•
Power cycle
•
Daily
See
"Calibrating Channel Power Measurements" on page 29
if necessary, and
then return to this procedure.
NOTE:
The following procedure assumes that an instrument PRESET will be performed as part of
setting up a call. This clears all settings from other tests that may affect the accuracy of this
test, and allows the procedure to begin from a known instrument state.
Содержание HP 8924C
Страница 21: ...Contents 21 N mkt MANUALS HP8924C APPMOD BOOK APPMOD TOC Table of Contents Index 351 ...
Страница 22: ...Contents 22 N mkt MANUALS HP8924C APPMOD BOOK APPMOD TOC ...
Страница 51: ...51 N mkt MANUALS HP8924C APPMOD BOOK chapters amcall fb Chapter 2 Setting Up a Call 2 Setting Up a Call ...
Страница 71: ...71 N mkt MANUALS HP8924C APPMOD BOOK chapters amrcvrt fb Chapter 3 CDMA Receiver Tests 3 CDMA Receiver Tests ...
Страница 139: ...139 N mkt MANUALS HP8924C APPMOD BOOK chapters amtxtst fb Chapter 4 CDMA Transmitter Tests 4 CDMA Transmitter Tests ...
Страница 199: ...199 N mkt MANUALS HP8924C APPMOD BOOK chapters amhoff fb Chapter 5 CDMA to Analog Handoff 5 CDMA to Analog Handoff ...
Страница 317: ...317 N mkt MANUALS HP8924C APPMOD BOOK chapters amsrq fb Chapter 10 Controlling Program Flow 10 Controlling Program Flow ...