295
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amcproc.fb
Chapter 9, 264 Using the Analog Call Processing Subsystem
Using the CALL CONTROL Screen to test AMPS Authentication
Cha
p
te
r 9
Usin
g the
Anal
og Ca
ll
Proce
s
s
ing Su
bsy
s
tem
6. Select the
Register
field. The
Register
annunciator will light while the registra-
tion is in process. If the mobile station responds properly on the reverse control channel,
the message
RECC Return
will flash momentarily in the upper right-hand corner of
the CALL CONTROL screen and then the mobile station’s phone number, ESN and de-
coded SCM will be displayed in the upper right-hand portion of the CALL CONTROL
screen. The information in the
MS Id
field will be updated. The
Active
annunciator
will light when the registration has successfully completed.
7. Select
AUTHEN
on the To Screen field. The AUTHENTICATION screen will be dis-
played.
8. Select the
A_KEY
field and enter a valid A_KEY in decimal format.
9. Position the cursor on the
Off/On
field and select
On
.
10. Select
CALL CNTL
from the
To Screen
menu. The CALL CONTROL screen will
be displayed.
11. Select
SSD Upd
in the
CC Order
field. The Access annunciator light will light while
the SSD Update order is in progress. If the mobile station responds properly on the re-
verse control-channel, “
SSD Update Order Successful
” will be displayed in
the upper right-hand portion of the CALL CONTROL screen. The test set and the mo-
bile station now share common secret data and further call processing functions with
authentication can be tested. If the order failed, then “
SSD Update Order
Failed
” will appear on the upper right-hand portion of the CALL CONTROL screen.
Initializing
Authentication without
Registration
1. Ensure that the Test Set is in the active state.
See "Turn On The Test Set’s Control
1. for information on how to activate the Test Set.
2. Connect the mobile station to the Test Set as shown in
figure 2, "Connecting a Mobile
Station to the Test Set," on page 269
.
3. Turn on the mobile station.
4. If the CALL CONTROL screen is not displayed, select
CALL CNTL
from the
To
Screen
menu. The CALL CONTROL screen will be displayed.
5. Position the cursor on the
Display
field and select
Data
.
6. Select the upper
MS ID
field and then
select
MIN2 MIN1
from the Choices: menu.
7. Select the lower
MS ID
field and enter the information in hexadecimal format.
8. Select
AUTHEN
from the To Screen menu. The AUTHENTICATION screen will be
displayed.
9. Select the A_KEY field and enter a valid A_KEY in decimal format.
10. Select the ESN field
and enter the mobile station’s electronic serial number in a
hexadecimal format.
11. Position the cursor on the
Off/On
field and select
On
.
12. Select
CALL CNTL
from the
To Screen
menu. The CALL CONTROL screen will
be displayed.
Содержание HP 8924C
Страница 21: ...Contents 21 N mkt MANUALS HP8924C APPMOD BOOK APPMOD TOC Table of Contents Index 351 ...
Страница 22: ...Contents 22 N mkt MANUALS HP8924C APPMOD BOOK APPMOD TOC ...
Страница 51: ...51 N mkt MANUALS HP8924C APPMOD BOOK chapters amcall fb Chapter 2 Setting Up a Call 2 Setting Up a Call ...
Страница 71: ...71 N mkt MANUALS HP8924C APPMOD BOOK chapters amrcvrt fb Chapter 3 CDMA Receiver Tests 3 CDMA Receiver Tests ...
Страница 139: ...139 N mkt MANUALS HP8924C APPMOD BOOK chapters amtxtst fb Chapter 4 CDMA Transmitter Tests 4 CDMA Transmitter Tests ...
Страница 199: ...199 N mkt MANUALS HP8924C APPMOD BOOK chapters amhoff fb Chapter 5 CDMA to Analog Handoff 5 CDMA to Analog Handoff ...
Страница 317: ...317 N mkt MANUALS HP8924C APPMOD BOOK chapters amsrq fb Chapter 10 Controlling Program Flow 10 Controlling Program Flow ...