N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amtxtst.fb
Chapter 4, CDMA Transmitter Tests
Measuring Access Probe Output Power
Cha
p
te
r 4
CDM
A T
ra
n
s
m
itte
r
Te
s
ts
5. Set MAX_RSP_SEQ to 1.
HP-IB Syntax
"DISP CCNF" !displays the CELL SITE CONFIGURATION screen"
"CDMA:CELL:CONF:MAXR 1"
Manual Operation:
1. Press and release the SHIFT key and then press
the CALL CTRL key to display the CDMA
CELL SITE CONFIGURATION screen.
2. Position the cursor at the Max Req Seq
Max Rsp Seq field.
3. Use the knob to increment or decrement the
value to 1.
CDMA CELL SITE CONFIGURATION
Max Req Seq
Max Rsp Seq
1