194
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amtxtst.fb
Chapter 4, CDMA Transmitter Tests
Measuring Access Probe Output Power
8. Measure access probe power.
HP-IB Syntax
"CDMA:CALL:MAKE" !pages the MSUT
Manual Operation:
Press the CALL key on the Test Set’s front
panel to page the MSUT.
Nominal settings for the Spectrum Analyzer
are shown.
The figure above shows one access probe sequence, consisting of five access probes. In this test, the MSUT
will transmit three access probe sequences.
After the CALL key is pressed on the Test Set, the Page Sent annunciator will light to indicate that a paging
message was sent to the MSUT.
The Access Probe annunciator will light to indicate that the mobile station has transmitted at least one access
probe sequence in an attempt to gain system access.
Spectrum Analyzer:
Sweep Time: 5 s
Ref: -15.0 dBm
1 dB/Div
Span: 0 Hz
Содержание HP 8924C
Страница 21: ...Contents 21 N mkt MANUALS HP8924C APPMOD BOOK APPMOD TOC Table of Contents Index 351 ...
Страница 22: ...Contents 22 N mkt MANUALS HP8924C APPMOD BOOK APPMOD TOC ...
Страница 51: ...51 N mkt MANUALS HP8924C APPMOD BOOK chapters amcall fb Chapter 2 Setting Up a Call 2 Setting Up a Call ...
Страница 71: ...71 N mkt MANUALS HP8924C APPMOD BOOK chapters amrcvrt fb Chapter 3 CDMA Receiver Tests 3 CDMA Receiver Tests ...
Страница 139: ...139 N mkt MANUALS HP8924C APPMOD BOOK chapters amtxtst fb Chapter 4 CDMA Transmitter Tests 4 CDMA Transmitter Tests ...
Страница 199: ...199 N mkt MANUALS HP8924C APPMOD BOOK chapters amhoff fb Chapter 5 CDMA to Analog Handoff 5 CDMA to Analog Handoff ...
Страница 317: ...317 N mkt MANUALS HP8924C APPMOD BOOK chapters amsrq fb Chapter 10 Controlling Program Flow 10 Controlling Program Flow ...