160
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amtxtst.fb
Chapter 4, CDMA Transmitter Tests
Measuring Maximum RF Output Power
6. Measure average power.
HP-IB Syntax
"MEAS:CDM:AVGP?" !queries the Average Power measurement.
Manual Operation:
Read the average power measurement.
CDMA TRANSMITTER CLOSED LOOP RANGE TEST
Always Up
Closed Loop
Pwr Cntl
n up
150
Execute
Change
Steps
On/Off
Drop Timer
Max Power
dBm
Min Power
dBm
Avg Power
dBm
Ideal Mobile Power: XXX.X dBm
25.21