313
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amcproc.fb
Chapter 9, 264 Using the Analog Call Processing Subsystem
Using the ANALOG MEAS Screen
Cha
p
te
r 9
Usin
g the
Anal
og Ca
ll
Proce
s
s
ing Su
bsy
s
tem
Using the ANALOG MEAS Screen
The ANALOG MEAS screen combines some of the Test Set’s
Audio Analyzer
fields and some of the Test Set’s RF Generator fields onto one screen for the
purpose of testing the audio characteristics of the mobile station. Only those fields
which are pertinent to testing the mobile stations audio characteristics have been
combined onto the ANALOG MEAS screen. The Test Set must be in the
connected state (that is, the
Connect
annunciator is lit) in order to use the
ANALOG MEAS screen.
The mobile station’s speaker output must be connected to the Test Set’s AUDIO
IN connector and the mobile station’s microphone input must be connected to the
Test Set’s AUDIO OUT connector in order to use the ANALOG MEAS screen.
Refer to
Figure 2, "Connecting a Mobile Station to the Test Set," on page 269
connection information. If the mobile station does not have audio connections the
ANALOG MEAS screen cannot be used.
There are a wide variety of audio measurements which can be made from the
ANALOG MEAS screen. The following examples illustrate how to make a
typical mobile station receiver measurement (RF Sensitivity) and a typical mobile
station transmitter measurement (FM Hum and Noise).
To Make an RF Sensitivity Measurement
1. If not already done, condition the Test Set.
See "Conditioning the Test Set for Call
for further information.
2. If not already done, configure the Test Set.
See "Configure the Test Set" on page 286
for further information.
3. Connect the mobile station to the Test Set as shown in
bile Station to the Test Set," on page 269
.
NOTE:
The mobile station’s speaker output must be connected to the Test Set’s AUDIO IN and the
mobile station’s microphone input must be connected to the Test Set’s AUDIO OUT in
order to use the ANALOG MEAS screen.
4. Turn on the mobile station.
5. Ensure that the Test Set is in the connected state.
See "Page a Mobile Station" on
for information on how to bring a mobile station up on a voice channel.
6. If the ANALOG MEAS screen is not displayed, select the
ANLG MEAS
field from the
To Screen
menu. The ANALOG MEAS screen will be displayed.
7. The following example illustrates how to make a 12 dB SINAD Receiver Sensitivity
measurement:
a
Select the
AFGen1 Freq
field and set it to 1 kHz.
b
Select the upper
AFGen1 To
field and set it to
FM
.
Содержание HP 8924C
Страница 21: ...Contents 21 N mkt MANUALS HP8924C APPMOD BOOK APPMOD TOC Table of Contents Index 351 ...
Страница 22: ...Contents 22 N mkt MANUALS HP8924C APPMOD BOOK APPMOD TOC ...
Страница 51: ...51 N mkt MANUALS HP8924C APPMOD BOOK chapters amcall fb Chapter 2 Setting Up a Call 2 Setting Up a Call ...
Страница 71: ...71 N mkt MANUALS HP8924C APPMOD BOOK chapters amrcvrt fb Chapter 3 CDMA Receiver Tests 3 CDMA Receiver Tests ...
Страница 139: ...139 N mkt MANUALS HP8924C APPMOD BOOK chapters amtxtst fb Chapter 4 CDMA Transmitter Tests 4 CDMA Transmitter Tests ...
Страница 199: ...199 N mkt MANUALS HP8924C APPMOD BOOK chapters amhoff fb Chapter 5 CDMA to Analog Handoff 5 CDMA to Analog Handoff ...
Страница 317: ...317 N mkt MANUALS HP8924C APPMOD BOOK chapters amsrq fb Chapter 10 Controlling Program Flow 10 Controlling Program Flow ...