12.3 Faults and Warnings
The table below provides details of possible error.
Message
Description
Action
W-01
Calibration needed
The unit has not been calibrated for the
configured calibration interval
Calibration is necessary due to change
of sensor/gas type
W-02
Transmitter Temperature
limits exceeded
Use ‘
’ to clear when within limits
W-03
Alarm setting needs to be
configured
Re-configure alarm settings such that
upper alarm should not exceed user
configured scale
W-04*
Over-range warning
Use ‘
’ to clear when within limits
W-05*
The sensor is switched off
to prevent it from being
deteriorated
Make sure that there is no flammable
gas in the air and use ‘
’ to clear when
within limits
F-01
Internal I2C failure
Cycle power to detector. Replace
detector
F-02
Cell failure
For Flammable/IR, cycle power to
detector. Replace sensor
F-03
Significant zero drift
Re zero/calibrate
F-04
Unexpected sensor fitted
Replace sensor
F-05
EEPROM is corrupted
Reset transmitter. If fault still appear,
replace transmitter
F-06
Low supply voltage
Reset transmitter. If fault still appear,
replace transmitter
F-07
SRS processor failure
Reset transmitter. If fault still appear,
replace transmitter
F-08
RAM read/write fault
Reset transmitter. If fault still appear,
replace transmitter
F-09
Info. memory corrupted
Reset transmitter. If fault still appear,
replace transmitter
F-10
Code Memory corrupted
Reset transmitter. If fault still appear,
replace transmitter
F-11
DAC output failure
Check load resistor or sink/source mode
switch was configured properly
F-12
Heater failure
Reset transmitter. If fault still appear,
replace transmitter
F-13
Supplied voltage failure
Check supply voltage. Replace detector
*Note : W-04 and W-05 are only for flammable catalytic bead sensors. For other gases, gas reading will blink on the LCD
instead of the over-range warning.
Table 9: Fault and Warning List
Содержание Sensepoint XCD RFD
Страница 1: ...Technical Handbook Sensepoint XCD RFD Remote Flammable Detector ...
Страница 59: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 59 17 6 Mounting Bracket Drawing ...
Страница 60: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 60 17 7 Sensepoint XCD RFD Sensor ...
Страница 64: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 64 China GB Ex English Version ...
Страница 65: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 65 China PA Certification ...
Страница 66: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 66 18 2 Korea KTL ...
Страница 67: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 67 18 3 European ATEX ATEX For Transmitter ...
Страница 68: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 68 ATEX for Sensor ...
Страница 70: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 70 IEC Ex for Sensor ...
Страница 79: ...www norrscope com ...