8.3 Magnetic Wand Activation
The magnetic wand is used as a tool to allow the user
to communicate with the Sensepoint XCD RFD transmitter.
Communication with the XCD RFD is achieved by positioning
the Magnetic Wand at one of three different positions on
the front glass window of the Sensepoint XCD RFD transmitter.
Activation of the switches is verified by observing
the Magnetic Wand Activation Icon on the LCD display
Hold the Magnetic Wand in position for up to 2 seconds
=
Hold the Magnetic Wand in position for 3 seconds or more =
8.4 Operation Mode Structure
Sensepoint XCD RFD has 3 operating modes.
1.
Monitoring mode
, is the normal operating status while XCD RFD measures and
displays gas concentration. The fault/warning status is periodically checked, relay
contacts are activated according to the configuration.
2.
Configuration mode
, this mode allows parameters relating to the configuration of
the Transmitter functions to be changed according to specific needs. This mode can
be protected by a password mechanism to prevent unauthorised changes being
made.
3.
Review mode
, allows the user to view the current configuration settings.
Diagram 11: Mode Structure
Further details of the information available and configuration options for the Sensepoint
XCD RFD can be found in Section 13. of this manual.
Start - Up
Configuration
Mode
Review
Mode
Monitoring
Mode
Содержание Sensepoint XCD RFD
Страница 1: ...Technical Handbook Sensepoint XCD RFD Remote Flammable Detector ...
Страница 59: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 59 17 6 Mounting Bracket Drawing ...
Страница 60: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 60 17 7 Sensepoint XCD RFD Sensor ...
Страница 64: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 64 China GB Ex English Version ...
Страница 65: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 65 China PA Certification ...
Страница 66: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 66 18 2 Korea KTL ...
Страница 67: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 67 18 3 European ATEX ATEX For Transmitter ...
Страница 68: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 68 ATEX for Sensor ...
Страница 70: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 70 IEC Ex for Sensor ...
Страница 79: ...www norrscope com ...