Sensepoint XCD RFD Technical Manual
SPXCDHMRFEN Issue 4_08-2016
11
4.4 Options
4.4.1 Modbus
®
One of the most common field buses in the industry, the optional Modbus
®
interface allows
the XCD to connect to a bus of devices and transmit data to PLCs or controllers (see
Appendix A). Connections to the XCD are made through a pluggable terminal block on
the Modbus
®
interface circuit board. Modbus
®
RTU protocol uses ASCII/Hex protocols for
communication. And allows all transmitter/sensor front panel functions to be transmitted
using this industrial fieldbus.
Modbus
®
protocol is a Master-Slaves protocol. Only one master (at the same time) is
connected to the bus and one or up to 32 slave nodes are also connected to the same
serial bus. Modbus
®
communication is always initiated by the master. The slave nodes will
never transmit data without receiving a request from the master node. The slave nodes
will never communicate with each other. The master node initiates only one Modbus®
transaction at the same time.
The MODBUS
®
may only be used for data collection or record keeping with regard to
combustible gas detection and not for performance verification.
Modbus
®
option is available only for selected gases. Please refer to chapter 15 Ordering
information.
To find out if a unit has the Modbus
®
option fitted, look at the part number on the product
label. Units fitted with Modbus
®
have the letter “M” at the end of the part number.
Note: MODBUS
®
is a registered trademark of Schneider Automation Inc.
Содержание Sensepoint XCD RFD
Страница 1: ...Technical Handbook Sensepoint XCD RFD Remote Flammable Detector ...
Страница 59: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 59 17 6 Mounting Bracket Drawing ...
Страница 60: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 60 17 7 Sensepoint XCD RFD Sensor ...
Страница 64: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 64 China GB Ex English Version ...
Страница 65: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 65 China PA Certification ...
Страница 66: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 66 18 2 Korea KTL ...
Страница 67: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 67 18 3 European ATEX ATEX For Transmitter ...
Страница 68: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 68 ATEX for Sensor ...
Страница 70: ...Sensepoint XCD RFD Technical Manual SPXCDHMRFEN Issue 4_08 2016 70 IEC Ex for Sensor ...
Страница 79: ...www norrscope com ...