Section 2: Mounting and Wiring
2-7
Power Connections and Options
Powering the Communication Module (dedicated power source)
Primary power for the communications module is provided by the AC plug-in transformer
(see
Figure 2-10
). However if using the LYNXR-I, primary power is supplied by the LRR/IP
communication port (see
Figure 2-3
).
In all installations, TB1-4 GND must be connected to ground (GND) on the control panel.
NOTE:
When calculating the total load on the auxiliary power output of the control panel,
allow 10mA for the communications module.
iGSMBR-013-V0
12V AUX
GND
COMMUNICATIONS
MODULE
CONTROL PANEL
GND
ECP (+) VOLTAGE INPUT
2
1
4
3
TB1
TRANSFORMER
AC INPUT 2
AC INPUT 1
J1
BATTERY
Figure 2-10. Dedicated Power Source
Powering the Communication Module (shared power source)
If shared power is desired, you must use the Model 1361 (16.5V, 40VA) transformer provided to
power both the residential control panel (e.g., VISTA-10P, VISTA-15P, VISTA-20P) or
commercial burglary control panel (e.g., VISTA-128BP Series) and the communications
module.
To wire the 1361 transformer, refer to
Figure 2-11.
CONTROL PANEL
TO 110 VAC
UNSWITCHED
OUTLET
iGSMBR-014-V0
1 2
30 FT. MAX TO MODULE
18 AWG. WIRE (MIN)
1361
TRANSFORMER
2
1
COMMUNICATIONS
MODULE
Figure 2-11. Shared Power Source
Содержание AlarmNet GSMBR
Страница 2: ......
Страница 38: ...GSMBR iGSMBR Installation and Setup Guide 3 22 ...
Страница 50: ...GSMBR iGSMBR Installation and Setup Guide A 2 ...
Страница 54: ...GSMBR iGSMBR Installation and Setup Guide C 2 ...
Страница 57: ...NOTES ...
Страница 58: ...NOTES ...
Страница 59: ...NOTES ...
Страница 60: ...NOTES ...
Страница 61: ...NOTES ...
Страница 62: ...NOTES ...