Data Field Programming
4-3
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*29
ECP Contact ID Output for ACM
0 = not used
1 = use Contact ID output on ECP
If selected, all messages programmed to go to the
primary telephone line receiver will also be sent (in
Contact ID format) to the connected Alternative
Communication Media (ACM), such as a 7845i
Internet/Intranet Communicator or
AI4164RS/AI4164ETH Eureka Network Interface, or
7845C/7835C cellular radio (in selected countries). The
data line is supervised as well as certain functions in a
long range radio. If communication is lost or a trouble
develops, an attempt will be made to send a message
via both ACM and telephone to the central station.
Program the ACM for device address 3.
Zone Sounds & Timing
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*31
Single Alarm Sounding Per Zone
Dialer/Bell Disable if Arm Stay
0 -7 = see table of entries at right
Select whether a zone going into alarm should sound
more than once per armed period and whether Bell
and/or Dialer should be disabled if armed STAY.
Entry Single
Alarm
Sound
Disable Bell if
Armed STAY
Disable Dialer
if Armed STAY
0 No
No
No
1 Yes
No
No
2 No
Yes No
3 Yes
Yes
No
4 No
No Yes
5 Yes
No
Yes
6 No
Yes Yes
7 Yes
Yes Yes
*32
Fire Alarm Sounder Timeout
0 = yes; fire sounder timeout after time
programmed in field
∗
33
1 = no fire sounder timeout; continue
sounding until manually turned off
Select whether fire alarm sounding expires after
sounder timeout or remains until manually turned off.
*33
Siren Timeout
0 = No timeout
4 = 4 min
1 = 1 min
5 = 8 min
2 = 2 min
6 = 16 min
3 = 3 min
This field determines whether the external sounder
will shut off after time allotted, or continue until
manually turned off.
*34
Exit Delay
00 - 96 = 0 - 96 seconds
97 = 120 seconds
The system waits the time entered before arming
entry/exit zones. If the entry/exit door is left open after
this time expires, an alarm will occur or the zone will
be auto-bypassed, depending on the selection in field
*88. Common area zones use same delay as partition 1.
*35
Entry Delay 1
00 - 96 = 0 - 96 seconds
97 = 120 seconds
98 = 180 seconds
99 = 240 seconds
Upon entering, the system must be disarmed before
the time entered expires, otherwise it sounds an alarm.
Common area zones use same delay as partition 1.
When an entry delay zone is activated, the entry delay
time applies to ALL burglary zones in the partition.
EN50131-1 Compliance: Entry delay must be at least
30 seconds, but may not exceed 45 seconds.