Pager Programming Fields
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*160
Pager 1 Phone No.
Enter up to 20 digits
If you enter fewer than 20 digits, exit by pressing [
∗
]
and next field number. To clear entries from this field,
press
∗
160
∗
.
*161
Pager 1 Characters
Enter up to 16 characters
Up to 16 optional characters may be sent as a prefix to
the 7-digit system status code sent to pager #1 (if
used). Phone number in field *160 must have been
entered. If fewer than 16 characters, exit by pressing
[
∗
] and next field number. To clear entries from this
field, press
∗
161
∗
.
For example, use these optional 16 characters for the
following:
•
PIN number (to identify a specific pager to the
paging company)
•
Subscriber account number
•
∗
(enter # + 11 to send
∗
); # (enter # + 12 to send #)
•
Pause (enter # + 13 to allow a 2-second pause)*
•
Any special character(s) the end user may decide to
transmit
* Some paging systems require pause(s) before the
prefix.
The format for the 7-digit system status code is defined
as follows:
Pager Format: XXX-YYYY where:
XXX
= 3-digit event code: 911 = Alarm
811
=
Trouble
101 = Opening (disarm)
102 = Closing (arm)
YYYY
= 4-digit user or zone number (depending on
type of event).
The first digit indicates partition, followed
by 0, then the 2-digit user or zone number.
Example 1.
Pager displays: 9 1 1 – 1 0 0 4
This indicates that the system is reporting an alarm
(911) caused by a fault in zone 4 in partition 1.
Example 2.
Pager displays: 1 0 2 – 2 0 0 5
This indicates that the system is reporting a closing–
system arming (102) by User 5 in partition 2.
*162
Pager 1 Report Options
0 = No reports sent
1 = Open/close for all users enabled to page
4 = All alarms and troubles
5 = All alarms, troubles, and open/close for
all users enabled to page
12 = Alarms and troubles for zones entered
in zone list 9
13 = Alarms and troubles for zones listed in
zone list 9 and opens/closes for all
users enabled to page
Enter the types of reports to be sent to pager 1 for each
partition.