Installation and Setup Guide
4-16
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*176
Siren Options
Entry 1: 0 = external siren
1 = self-activated external siren
Entry 2: 0 = disable delay
1 = enable 30 second siren delay
and dialer delay during entry
delay period
2 = enable stay siren delay
Select desired options.
Entry 2, if 1: When entry delay is active and an instant
zone is faulted, the siren is delayed 30 seconds and the
report is delayed 30 seconds, unless field *50 is set for a
greater delay (the 30-second dialer delay supersedes
values less than 30 seconds set in field *50).
Entry 2, if 2: When armed in the Stay mode and an
alarm event occurs, the siren output will be delayed by
the amount of time that the entry delay 1 is set for.
*177
Device Duration 1, 2
Duration 1:
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
#+13 = 10 min
2 = 45 secs
8 = 4 min
#+14 = 12 min
3 = 60 secs
9 = 5 min
#+15 = 15 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
Duration 2: 1 through 7 for number of days
These entries set the duration for output action options
5 (duration 1) and 6 (duration 2) programmed in
∗
80
Output Function Programming.
Duration 2 can be used as a strobe timer.
*178
RF Supervision / RF Jam Option
0 = RF supervision and RF jam detection
reporting
1 = Report RF supervision failure as tamper
alarm when armed
2 = Report RF Jam as tamper alarm when
armed
3 = Report RF Jam and RF supervision
failure as tamper alarm when armed**
Select desired option. See field *22 for related options.
Entry 0: RF jam conditions report as Trouble zone 90
(Contact ID code 344, RF Rcvr Jam Detect)
plus a zone trouble report for each RF zone in
the system (CID code 383, Trouble Sensor
Tamper) when the system is armed or
disarmed. Keypads display Tamper zz (zz =
zones) and Tamper 90 (fixed-word) or
RECEIVER JAM (alpha).
RF supervision failures report as zone troubles
(CID code 381, RF Sensor Super.) when the
system is armed or disarmed. Keypads display
CHECK zz (zz = zone).
Entry 1: Same as entry 0 except RF supervision failures
report as zone alarms (CID code 144, Alarm
Sensor Tamper) when the system is armed;
keypads display ALARM zz.
Entry 2: Same as entry 0 except RF jam conditions
report as zone alarms (Contact ID code 144,
Alarm Sensor Tamper) when the system is
armed; keypads display ALARM zz.
Entry 3: Same as entry 0 when disarmed, but when the
system is armed, both RF jam conditions and
RF supervision failures report as zones alarms
(Contact ID code 144, Alarm Sensor Tamper)
NOTES:
RF Jam must be enabled in field *22 in order
for
any
RF reporting to be enabled in this field.
Alarm restore reports must be enabled (field *70) in
order for RF Supervision/RF Jam alarm restores to be
reported.
Trouble reports and trouble restore reports must be
enabled (fields *60, *71) in order for RF supervision/RF
jam trouble conditions and restores to be reported.
** Must be “3” for
prEN50131-5-3
Class 2 compliance
Содержание Ademco Vista-12D
Страница 2: ...Installation and Setup Guide ii ...
Страница 8: ...Installation and Setup Guide 1 4 ...
Страница 36: ...Installation and Setup Guide 3 10 ...
Страница 100: ...Installation and Setup Guide 7 4 ...
Страница 106: ...Installation and Setup Guide 8 6 ...