Data Field Programming
4-5
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*41
Primary Phone No.
Enter up to 30 digits. Do not fill unused
spaces.
0–9, # + 11 for ‘
∗
’, # + 12 for ‘#’, # + 13 for a
pause (2 seconds)
If you enter fewer than 30 digits, exit by pressing [
∗
].
To clear entries from field, press
∗
41
∗
.
NOTE:
Backup reporting (in which 8 calls are made to
the secondary phone number if no kissoff is received
after 8 attempts to the primary number) is automatic
only if there is a secondary phone number (field
∗
42).
*42
Secondary Phone No.
Enter up to 30 digits. 0–9, # + 11 for ‘
✱
’, # +
12 for ‘#’, # + 13 for a pause (2 seconds)
If you enter fewer than 30 digits, exit by pressing [
∗
].
To clear entries from field, press
∗
42
∗
. See backup
reporting note for field
∗
41. Don’t fill unused spaces.
*43
Part. 1 Primary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format
selected in field *48. To clear entries from field, press
∗
43
∗
.
*44
Part. 1 Secondary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format
selected in field *48. To clear entries from field, press
∗
44
∗
.
*45
Part. 2 Primary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format
selected in field *48. To clear entries from field, press
∗
45
∗
.
*46
Part. 2 Secondary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format
selected in field *48. To clear entries from field, press
∗
46
∗
.
*47
Phone System / Dialer Attempts
Phone System Select:
If Central Station Receiver
is
not
on satellite
link: 0 = Decadic Pulse Dial;
1 = Multifrequency Tone Dial
If Central Station Receiver
is
on satellite link:
2 = Decadic Pulse Dial;
3 = Multifrequency Tone Dial
Dialer Attempts:
1 – 10 (for 10, enter #+10)
Phone System Select:
Select the type of telephone
service.
Dialer Attempts:
Enter the number of times the
system should attempt to dial the central station, 1 –
10 times (for 10, enter #+10).
*48
Report Format
(Primary/Secondary)
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = CID* using 10-digit account number
6 = 4+2 ADEMCO EXPRESS
7 = CID* using 4-digit account number
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
10 = ROBOFON 8 (6-digit account number)
11 = ROBOFON Contact ID
Select report format for primary and secondary phone
numbers.
* ADEMCO Contact ID format
NOTE:
To enable the audio “beeps” format (Follow-Me
feature), refer to the System Features section later in
this manual, and the User Guide.
*49
Split/Dual Reporting
0 = disable (standard/backup report only).
1 - 5 (see table to right)
To Primary No.
To Secondary No.
1 = alarms, restore, cancel
others
2 = all except open/close, test
open/close, test
3 = alarms, restore, cancel
all
4 = all except open/close, test
all
5 = all
all