Menu Mode Programming
5-15
PROMPT
VALID ENTRIES
EXPLANATION
XX REL POSITION
1-4 zz
Relay Position
1-4 = relay position
[
∗
] to continue
This is the actual (or physical) relay number with
respect to the Relay Module upon which it is
located. For 4204 modules, relay numbers are 1-4.
For 4229 modules, relay numbers are 1-2; for 6164
the relay number is 1.
The system returns to the Output Number prompt
for programming the next device.
*80 Menu Mode: Defining Output Functions
Use this mode to program output function definitions (up to 12 functions) that provide automated
control of any of the output devices, based on events occurring on individual zones or zones with certain
zone types. Each output definition is identified by an output function number, and includes the
following components:
Output Definition Components
Component Description
Output Function No.
A reference number that defines an output’s characteristics.
Activated By
Determines whether the initiating event occurs on a zone, a zone list, or a
zone type.
Event
Event that triggers the output action. Can be an event occurring on a specific
zone number or a zone list or a specific zone type.
Partition
If the output is activated by zone type, this defines the partition in which the
programmed event is to cause the device action.
Output Action
Defines the action of the relay/X-10 device when the defined event occurs.
Can close for 2 seconds, stay closed until reset, continuously pulse (1-second
close-open-close-open, etc.), toggle the device state, or activate for a defined
duration (set in data field *177).
Output No.
Assigns this function to a specific output number (defined in *79 Menu
Mode). This is the output number that will perform this function upon the
triggering event. Note that each defined function is associated with only one
output number. This means that if more than one output device needs to
perform this particular function, you need to define another output function
number with the same attributes, but assign the appropriate output number.
(i.e. output devices can be assigned more than one function number, but each
function number can only be assigned a single output number.