![Honeywell Ademco Vista-12D Скачать руководство пользователя страница 95](http://html.mh-extra.com/html/honeywell/ademco-vista-12d/ademco-vista-12d_installation-and-setup-manual_153258095.webp)
System Communication and Operation
6-11
Various System Trouble Displays
Alpha Display
Fixed Disp.
Meaning
CANCELED ALARM
CA
Appears if an exit or interior zone contained a fault during closing at
the time the Exit Delay ended (e.g., exit door left open and the zone
was not auto-bypassed), but the system was disarmed during the
Entry Delay time. The alarm sounder and keypad sounder stop when
the system is disarmed. No message will be transmitted to the central
station.
EXIT ALARM
EA
will appear when the Exit Delay ends if an exit or interior zone
contained a fault during closing and the zone was not auto-bypassed.
The alarm sounder and keypad sound continuously until the system is
disarmed (or timeout occurs). An “Exit Alarm” message is sent to the
central station if enabled in field *59. Also results if an alarm from an
exit or interior zone occurs within 2 minutes after the end of an Exit
Delay if exit alarm is enabled in field *59.
CHECK CHECK
indicates that a problem exists with the displayed zone(s) and
requires attention.
ALARM 1xx
1xx
indicates that communication between control and a zone expander or
wireless
FAULT 1xx
1xx
receiver is interrupted, where “xx” is the device address. Check the
wiring and
CHECK 1xx
1xx
DIP switch settings on the units.
91
If field *199 is set to “1,” all ECP module problems are displayed as
“91.”
If there are wireless sensors in the system, the Check condition may
also be caused by some change in the environment that prevents the
receiver from receiving signals from a particular sensor.
TAMPER 1xx
1xx
Appears when a tamper switch at the device address shown has been
activated while system is disarmed.
TMPR_ARMD 1xx
Appears when a tamper switch at the device address shown has been
activated while system is armed.
SYSTEM LO BAT
BAT
with no zone number indicates that the system's main standby
battery is weak.
LO BAT
BAT
with a zone number and a once-per-minute beeping at the keypad
indicates that a low-battery condition exists in the wireless sensor
displayed (zone “00” indicates a wireless keypad). If the battery is not
replaced within 30 days, a “CHECK” display may occur.
Note: Some wireless sensors contain a non-replaceable long-life
battery which requires replacement of the entire unit at the end of
battery life (e.g., 5802 and 5802CP).
TELECOM FAULT
94
Telephone Line Failure, indicates that a monitored telephone line (if
programmed in field *92) has been cut or disconnected. Depending on
how the system was programmed, the keypad may also produce a
trouble sound, and the external sounder may be activated. Silence by
entering installer code + OFF.
Busy-Standby dl
If this remains displayed for more than 1 minute, the system is
disabled.
Modem Comm
CC
The system is in communication with the central station for change of
function or status verification.