Mounting and Wiring the Control
2-3
Wiring to Keypads
1. Connect keypads to the control’s keypad
terminals as shown on the Summary of
Connections diagram.
Determine wire size using the Wiring Run
Chart below.
2. Set keypad addresses. Refer to the address
setting instructions included with the
keypads and set each keypad device
address according to the chart at right.
3. Program the keypad addresses, partition
assignments and sound options in data
fields *190-*196.
NOTE:
Each keypad must be assigned a
unique address,
starting at address 16
.
Keypads programmed with the same
address will give unpredictable results.
Supplementary Power (optional)
1. Connect as shown. Be sure to connect the
negative (–) terminal on the power supply
unit to terminal 4
(AUX –) on the control.
+
–
+
4
5
6
7
SUPPLEMENTARY
POWER SUPPLY
–
CONTROL TERMINAL STRIP
AUX. AUX. DATA
IN
DATA
OUT
IMPORTANT:
MAKE THESE
CONNECTIONS
DIRECTLY TO
SCREW
TERMINALS AS
SHOWN.
TO KEYPAD RED POWER WIRE (V+)
TO KEYPAD BLK GROUND WIRE (V-)
TO KEYPAD YEL DATA WIRE (<)
TO KEYPAD GRN DATA WIRE (>)
TO KEYPAD BLK GROUND WIRE (V-)
TO KEYPAD RED POWER WIRE (V+)
TO KEYPAD GRN DATA WIRE (>)
TO KEYPAD YEL DATA WIRE (<)
pwr_sup_conn-008-V0
Figure 3. Using a Supplementary Power
Supply
Notes
•
Typical Fixed-Word Display:
6128RF/6148/6150/6150RF/6150V
•
Typical Alpha Display: 6160/6160V/6160RF/6164
•
The system supports up to 8 keypads, which can
be assigned to partitions in any combination
(see program fields *190-*196).
•
For single 4-wire runs, determine the current
drain of all units, then refer to the Wiring Run
chart to determine the maximum length that can
be safely used for each wire size.
•
Use supplementary power if the control’s aux.
power load for all devices exceeds 600mA.
Suggested power supply: AD12612
Keypad Addresses
Keypad Address
Keypad Address
no. 1
16**
no. 5
20
no. 2
17
no. 6
21
no. 3
18
no. 7
22
no. 4
19
no. 8
23
** The
first keypad is address 16
, which is always
enabled and set for partition 1 with all sounds on.
Keypads powered from supplies that do
not have a backup battery will not
function if AC mains power is lost. Make
sure to power at least one keypad in
each partition from the control’s auxiliary
power output.