![Honeywell Ademco Vista-12D Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/honeywell/ademco-vista-12d/ademco-vista-12d_installation-and-setup-manual_153258056.webp)
Installation and Setup Guide
4-20
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*197
Exit Time Display Interval
0 = no display
1-5 = seconds between display refreshing
If enabled, keypads display the exit delay time
remaining after arming the system, with display
updates at the interval selected (i.e. if the exit delay is
30 seconds and “2” is selected in this field, the keypad
display refreshes every 2 seconds, displaying 30, 28,
26, 24, etc.).
An interval greater than “1” may be necessary for some
older keypads to allow users time to enter key presses
between display updates.
*198
Display Partition Number
0 = no
1 = yes
If selected, the partition number is displayed in the
upper-left corner of the display. This is useful when
using the GOTO partition function.
*199
ECP Device Fail Display
0 = 3-digit display (“1” + device address)
1 = 2-digit fixed-display as “91”
Select “0” if using Alpha keypads and/or 3-digit Fixed-
Word Display keypads (6148, 6150, 6160, 6164). ECP
faults for keypads and/or other peripheral ECP devices
will display “1” plus the device address (00-30) of
device causing the fault (e.g., faults on device 07
display as “107”).
Select “1” if using 2-digit Fixed-Word Display keypads
(e.g., certain 6128RF series keypads). If selected, ECP
faults for keypads and/or peripheral devices will
display as “91” on 2-digit displays, and “191” on 3-digit
or Alpha keypads.