![Honeywell Ademco Vista-12D Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/honeywell/ademco-vista-12d/ademco-vista-12d_installation-and-setup-manual_153258042.webp)
Installation and Setup Guide
4-6
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*50
Burglary Dialer Delay
0 = no dial delay
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
Provides delay of “BURGLARY ALARM” report to
the central station, which allows time for the
subscriber to avoid a false alarm transmission. This
delay does not apply to zone type 24 alarms (silent
burglary) or to 24-hour zone types 6, 7, and 8 (silent
panic, audible alarm, auxiliary alarm), which are
always sent as soon as they occur.
*51
Common Partition Primary Subs.
Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, # +
13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report
format selected in field *48.
*52
Common Partition Secondary Subs.
Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, # +
13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report
format selected in field *48.
*53
SESCOA/Radionics Select
0 = Radionics (0-9, B-F reporting)
1 = SESCOA (0-9 only reporting)
Select SESCOA or Radionics format.
Select 0 for all other formats.
*54
Dynamic Signaling Delay
0 = disabled (both signals sent)
1–15 = entry times a 15-second delay.
e.g., 1 = 15 seconds, 2 = 30 seconds, etc.
Intended for use with ECP Contact ID Output
reporting via ACM.
This field lets you select the time the panel should
wait for acknowledgment from the first reporting
destination (see
∗
55) before it attempts to send a
message to the second destination. Delays can be
selected from 0 to 225 seconds, in 15-second
increments. This delay is per message. If ”0” is
entered in this field, the control panel will send
redundant reports to both Primary Dialer and ECP
output.
*55
Dynamic Signaling Priority
0 = Primary dialer first;
1 = ECP Contact ID output first.
Intended for use with Alternative Communication
Media reporting.
You must also enable field
∗
29, ECP Contact ID
Output for ACM.
Select the initial reporting destination for messages
as follows:
Primary Dialer First selected (0):
•
If acknowledged before delay expires (see
∗
54),
then message will not be sent to ECP output.
•
If not acknowledged before delay expires, then
message is sent to both the Primary Phone No.
and ECP output.
ECP Contact ID Output First selected (1):
•
If acknowledged before delay expires, then
message will not be sent to the primary dialer.
•
If not acknowledged before delay expires, then
message is sent to both the Primary Phone No.
and ECP Contact ID output.