4-1
S E C T I O N 4
Data Field Programming
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
About Data Field Programming
The following pages list this control’s data fields in numerical order. Field numbers are listed
in the left column followed by a “Title and Data Entries” column, which lists the valid entries
for each field. Experienced installers can simply follow this column when programming the
data fields. The “Explanation” column provides explanatory information and special notes
where applicable.
Use the blank programming form to record the data for this installation.
Programming Data Fields
Data field programming involves making the appropriate entries for each of the data fields.
Start Data Field programming by entering the installer code + 8 + 0 + 0.
System Setup Fields
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*20
Installer Code
Enter 4 digits, 0-9
The Installer Code is used to assign the 4-digit Master
Security Code. See "Master Code" in the
System
Operation
section
for procedure.
*21
Quick Arm Enable
0 = do not allow quick arm
1 = allow quick arm
If enabled, a user code is not needed to arm the system.
Instead, users can press the [#] followed by an arming
key to arm the system.
However, the user code is always needed to disarm the
system.
*22
RF Options
Entry 1 - Jam detection
0 = no RF Jam detection; 1 = detect RF Jam*
Entry 2 – supervision interval
0 = 12 hours; 1 = 2 hours; 2 = 20 minutes
when disarmed/ 2 hours when armed
3 = 12 hrs for burg zones/ 3 hrs for fire zones
If jam detection enabled, a report is sent if the system
detects an RF jamming signal. See field *178 for other
jam/supervision options.
When using RF Receivers with 5800 series
transmitters, entry 2 should be 0 or 3.
* Must be selected for
prEN50131-5-3
Class 2
compliance.
*23
Quick (Forced) Bypass
0 = no quick bypass
1 = allow quick bypass (code + [6] + [#] )
All zones bypassed by this function will be displayed
after the bypass is initiated.