124
U0-42
Do output status visual display
Indication range
-
U0-59
Set frequency
Indication range
-100.00% - 100.00%
U0-60
Running frequency
Indication range
-100.00% - 100.00%
Display the current set frequency and operating frequency. 100.00 % corresponds to the maximum frequency of
the frequency inverter (F0 - 16).
U0-61
Operating state of frequency
inverter
Indication range
0
~
65535
Display the frequency inverter operation status information.
The data definition format is as follows:
U0-61
Bit0
0: shutdown; 1: forward rotation; 2: reversal
Bit1
Bit2
0: constant speed; 1: accelerating; 2: slow down
Bit3
Bit4
0: bus voltage is normal; 1: under voltage
U0-62
Current fault code
Indication range
0
~
99
Display the current fault code.
U0-65
Upper torque limit
Indication range
-200.00% - 200.00%
Display the current upper limit of the given torque.
U0-69
Frequency inverter module
radiator temperature
Indication range
0
℃~
120
℃
Display the temperature of the frequency inverter module IGBT.
The over-temperature protection values of IGBT modules of different models are different.