84
Function code
Name
Setting value
Functional description
F5-11
Terminal command mode
3
Three wire type 2
F5-00
X1 terminal function
selection
1
Operation enable
F5-01
X2 terminal function
selection
2
Positive and negative
direction of operation
F5-02
X3 terminal function
selection
3
Three - wire operation
control
K
Direction of
movement
0
Forward
1
Reversal
Figure 5 - 15 three-wire control modes 2
As shown in the figure above, the control mode is under the closed state of SB1 button, press the SB2 button
converter to run, K turns off the inverter and K closes the inverter. SB1 button turns off and the frequency inverter
stops immediately. During normal start-up and operation, it is necessary to keep the SB1 button closed, and the SB2
button command will take effect at the edge of the closing action.
F5 - 12 terminal UP/DOWN change rate
0.01Hz/s
~
65.535Hz/s [1.00Hz/s]
When setting terminal UP/DOWN to adjust the set frequency, the speed of frequency changes, that is, the
amount of frequency change per second.
F5 - 13 PULSE minimum input
0.00kHz
~
F5-15 [0.00HZ]
F5 - 14 PULSE minimum input corresponding settings
-100.0%
~
100.0% [0.00HZ]
F5 - 15 PULSE maximum input
F5-13
~
50.00KHZ [50.00KHZ]
F5 - 16 PULSE maximum input corresponding settings
-100.0%
~
100.0% [100.0%]
F5 - 17 PULSE filter time
0.00s
~
10.00s [0.01s]
This set of function codes is used to set the relationship between X5 pulse frequency and corresponding
settings.
The pulse frequency can only be input to the frequency inverter through X5 channel.
F5 - 18 X1 delay time
0.0s
~
3600.0s [0.00S]
F5 - 19 X2 delay time
0.0s
~
3600.0s [0.00S]
Operational
Stop
Reversal
Содержание HV480 Series
Страница 1: ...HV610 Series Frequency Inverter User Manual HNC Electric Limited ...
Страница 12: ...8 2 2 3 Frequency inverter control loop terminal description ...
Страница 13: ...9 ...
Страница 166: ...162 Appendix II Plastic shell dimensions and mounting dimensions Fig 1 R75G3 2R2G3 Fig 2 004G3 7R5G3 ...
Страница 167: ...163 Appendix III dimensions and mounting dimensions of sheet metal machines Fig 3 011G3 200G3 Fig 4 185G3 560G3 ...