Chapter 13 Option
13 - 4
“A” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Initial data
standard
200/400
Initial data
CHN
200/400
Initial data
EU
200/400
Units
A001
Frequency
source
Five options; select codes:
00
POT on ext. operator
01
Control terminal
02
Function F001 setting
03
Modbus network input
10
Calculate function output
01
←
←
A201
Frequency
source,
2
nd
motor
01
←
←
A002
Run
command
source
Three options; select codes:
01
Control terminal
02
Run key on keypad,
or digital operator
03
Modbus network input
01
←
←
A202
Run
command
source,
2
nd
motor
01
←
←
A003
Base
frequency
Settable from 30.0 Hz to the maximum
frequency(A004)
60.0 50.0
50.0
Hz
A203
Base
frequency,
2
nd
motor
Settable from 30.0 Hz to the 2
nd
maximum
frequency(A204)
60.0 50.0
50.0
Hz
A004
Maximum
frequency
Settable from the base
frequency to 400.0
60.0 50.0
50.0
Hz
A204
Maximum
frequency,
2
nd
motor
Settable from the 2
nd
base
frequency to 400.0
60.0 50.0
50.0
Hz
A011
[O/OI] input
active
range start
frequency
The output frequency corresponding to
the analog input range starting point,
range is 0.00 to 400.00
0.00
←
←
Hz
A012
[O/OI] input
active
range end
frequency
The output frequency corresponding to
the analog input range ending point,
range is 0.0 to 400.00
0.00
←
←
Hz
A013
[O/OI] input
active
range start
voltage
The starting point (offset) for the active
analog input range,
range is 0. to 100.
0.
←
←
%
A014
[O/OI] input
active
range end
voltage
The ending point (offset) for the active
analog input range,
range is 0. to 100.
100.
←
←
%
A015
[O/OI] input
start
frequency
enable
Two options; select codes:
00
Use offset (
value)
01
Use 0Hz
01
←
←
A016
Analog
input filter
Range n = 1 to 31,
1 to 31 :•2ms filter
31. 8 31
Spl.
A019
Multi-speed
operation
selection
Select codes:
00...Binary operation
(8 speeds selectable with 3 terminals)
01...Bit operation
(4 speeds selectable with 3 terminals)
00
←
←
A020
Multi-speed
freq. 0
Defines the first speed of a multi-speed
profile, range is 0.00 / start frequency to
400.0
A020 = Speed 0 (1st motor)
0.00
←
←
Hz
Содержание NES1-002LB
Страница 9: ......
Страница 21: ......
Страница 25: ......
Страница 28: ...Chapter 3 Exterior Views 3 3 ...
Страница 29: ...Chapter 4 Installation This chapter describes how to install the inverter 4 1 Precautions for installation 4 1 ...
Страница 30: ......
Страница 35: ......
Страница 53: ......
Страница 75: ......
Страница 154: ......
Страница 196: ......
Страница 203: ...Chapter 10 Troubleshooting This chapter describes the troubleshooting methods ...
Страница 204: ......
Страница 211: ......
Страница 219: ......
Страница 229: ......
Страница 289: ...Appendix Appendix A Appendix A 1 ...
Страница 290: ......
Страница 292: ...Appendix Appendix 2 ...