Chapter 5 Wiring
5 - 6
(3) Changeover switch description
Refer to section 3.2 for the location of the switches.
Category Symbol Name
Description
Electrical
characteristics
Digit
al
Input
Cont
act
5
4
3
2
1
Intelligent
input
terminals
5 functions from 35
functions can be assigned
to terminal 1 to 5. Sink or
source logic can be
selected.
Voltage between each input and PLC
- V(ON) = min.18V
- V(OFF) = MAX.3V
- Max. allowable voltage = 27VDC
- Load current 5mA (24V)
Output
Open
-colle
ctor
11
Intelligent
output
terminals
One function from 28
functions can be assigned.
Open collector output
Between 11 and CM2
- Voltage drop during ON=4V or less
- Max. allowable voltage = 27V
- Max allowable current = 50mA
CM2
Common for
intelligent
output
terminals
Common for the terminal
11.
Max. allowable current = 100mA
Rela
y
AL0
AL1
AL2
Intelligent relay
outputs
One function from 28
functions can be assigned.
(1-c contact)
Max. contact capacity
AL1-AL0 : AC250V,
2A(resistive),0.2A(inductive)
AL2-AL0 : AC250V,
1A(resistive),0.2A(inductive)
Min. contact capacity
AC100V, 10mA
DC5V, 100mA
Puls
e
train
FM
Digital pulse
train output
Pulse frequency
MAX.3.6kHz
Pulse voltage : DC0/10V output
Max. allowable current : 2mA
Symbol Name
Description
SW4
Termination resistor
changeover switch
Select able/disable of the termination resistor of RS485 port (RJ45)
OFF
(left side)
Termination resistor (100
Ω
)
Disable (Default)
ON
(right side)
Termination resistor (100
Ω
)
Able
SW5
RS485/OPE(RS422)
changeover switch
Select depending on the options and communication method, connected
to RS422/RS485 port.
OFF
(right side)
For operator (OPE-S/SR/SBK/SRmini),ProDriveNext
(Default)
ON
(left side)
For RS485 communication (Modbus-RTU)
SW6
Analog input (O/OI)
changeover switch
OFF
(left side)
Current input (0~20mA) OI
ON
(right side)
Voltage input (0~10Vdc) O (Default)
- Adjustment of the switch must be done during power off. Otherwise there is a risk of electric shock.
- Power ON must be done after closing the front cover. Do not open the front cover during power up, or when
there is a remaining voltage. There is a risk of electric shock.
CAUTION
Содержание NES1-002LB
Страница 9: ......
Страница 21: ......
Страница 25: ......
Страница 28: ...Chapter 3 Exterior Views 3 3 ...
Страница 29: ...Chapter 4 Installation This chapter describes how to install the inverter 4 1 Precautions for installation 4 1 ...
Страница 30: ......
Страница 35: ......
Страница 53: ......
Страница 75: ......
Страница 154: ......
Страница 196: ......
Страница 203: ...Chapter 10 Troubleshooting This chapter describes the troubleshooting methods ...
Страница 204: ......
Страница 211: ......
Страница 219: ......
Страница 229: ......
Страница 289: ...Appendix Appendix A Appendix A 1 ...
Страница 290: ......
Страница 292: ...Appendix Appendix 2 ...