Chapter 12 Specifications
12 - 2
Common specification
Item Spec
Protective housing
(
JIS C 0920,IEC60529
)
IP20
Control
Control method
Sinusoidal Pulse Width Modulation (PWM) control
Output frequency range Note4
)
0.1 to 400 Hz
Frequency accuracy Note5
)
Digital command:
0.01% of the maximum frequency
Analog command:
0.4% of the maximum frequency (25
C
10
C)
Frequency setting resolution
Digital input: 0.01 Hz
Analog input: Maximum output frequency/1000
Volt./Freq. characteristic
V/f control (constant torque, reduced torque)
Overload capacity
150%/60 seconds
Acceleration/deceleration time
0.00 to 3,600.0 seconds (in linear or curved pattern)
、
2nd motors setting is possible
Input signal
Freq. setting
External signal
:
adjustable resistor / 0 to +10 VDC /0 to 20 mA,
Modbus
、
Option operator
、
Dedicated operator
RUN/STOP Order
External digital input signal
(
3-wire input possible
)
, Modbus
Option Operator
、
Dedicated Operator
Intelligent input terminal
5terminals
Analog input
1terminal
(
O/OI terminal
:
Voltage input10bit/0 to 10V, Current input
:
10bit/0 to 20mA
selecting it with a changeover switch
)
Output
signal
Intelligent output terminal
5 open-collector output terminals, 1 relay (1c-contact) output terminal
Pulse Output
1terminal
connection
RS-422
RJ45 Connector ,(Common with RS485
:
selecting it with a changeover switch
)
Option
Operator,ProDriveNext
RS-485
RJ45 Connector ,( Common with RS422
:
selecting it with a changeover switch
)
Modbus-RTU
Gene
ral
specificat
ion
Temperature Note6
)
Operating (ambient): -10 to 50
C, / Storage: -20 to 65
C
Humidity
20 to 90% humidity (non-condensing)
Vibration 5.9m/s
2
(0.6G), 10 to 55 Hz
Location
Altitude 1,000m or less, indoors (no corrosive gasses or dust)
Standards Compliance
UL
、
CE
、
c-UL
、
c-tick
Note1
)
The applicable motor refers to Hitachi standard 3-phase motor (4p). When using other motors, care must be taken to
prevent the rated motor current (50/60Hz) from exceeding the rated output current of the inverter.
Note2
)
The output voltage decreases as the main supply voltage decreases (except when using the AVR function). In any case,
the output voltage cannot exceed the input power supply voltage.
Note3
)
The braking torque via capacitive feedback is the average deceleration torque at the shortest deceleration (stopping from
50/60Hz as indicated). It is not continuous regenerative braking torque. The average deceleration torque varies with
motor loss. This value decreases when operating beyond 50Hz.
Note4
)
To operate the motor beyond 50/60Hz, consult the motor manufacturer for the maximum allowable rotation speed.
Note5
)
To get motor stabilized operation, inverter output Frequency might exceeds preset maximum Freq.(A004/A204) by 2Hz in
maximum.
Note6
)
Derating curve is shown on section 12.3.
Note7
)
Connecting work on RJ45 jack must be done during the inverter power off.
Note8
)
"*" changes by Restricted Distribution.
Содержание NES1-002LB
Страница 9: ......
Страница 21: ......
Страница 25: ......
Страница 28: ...Chapter 3 Exterior Views 3 3 ...
Страница 29: ...Chapter 4 Installation This chapter describes how to install the inverter 4 1 Precautions for installation 4 1 ...
Страница 30: ......
Страница 35: ......
Страница 53: ......
Страница 75: ......
Страница 154: ......
Страница 196: ......
Страница 203: ...Chapter 10 Troubleshooting This chapter describes the troubleshooting methods ...
Страница 204: ......
Страница 211: ......
Страница 219: ......
Страница 229: ......
Страница 289: ...Appendix Appendix A Appendix A 1 ...
Страница 290: ......
Страница 292: ...Appendix Appendix 2 ...