Chapter 13 Option
13 - 48
“C” Function
Run
Mod
e
Edit
Defaults
Func.
Code
(WOP)
Name
Description
Initial data
standard
200/400
Initial data
CHN
200/400
Initial data
EU
200/400
Unit
s
C074
(Parity)
Communication
parity
Three option codes:
00
No parity
01
Even parity
02
Odd parity
00
←
←
C075
(Stop bit)
Communication stop
bit
Two option codes:
01
1 bit
02
2 bit
1
←
←
C076
(Comm.error mode)
Communication error
select
Selects inverter
response to
communications
error.
Five options:
00
Trip
01
Decelerate to a
stop and trip
02
Disable
03
Free run stop
(coasting)
04
Decelerates to
a stop
02
←
←
C077
(Comm.timeout)
Communication error
time-out
Sets the
communications
watchdog timer
period.
Range is 0.00 to
99.99 seconds.
0.00= disabled
0.00
←
←
s
C078
(Comm.wait time)
Communication wait
time
Time the inverter
waits after receiving
a message before it
transmits.
Range is 0. to 1000.
m seconds.
0.
←
←
ms
C081
([O/OI] input adj.)
O/OI input span
calibration
Scale factor
between the
external frequency
command on
terminals L–O
/OI(voltage/current
input) and the
frequency output,
range is 0.0 to
200.0%
100.0
←
←
%
C091
(Debug mode
select)
Debug mode enable
*
Displays debug
parameters.
Two option codes:
00
Disable
01
Enable
<Do not set>
(for factory use)
00
←
←
Содержание NES1-002LB
Страница 9: ......
Страница 21: ......
Страница 25: ......
Страница 28: ...Chapter 3 Exterior Views 3 3 ...
Страница 29: ...Chapter 4 Installation This chapter describes how to install the inverter 4 1 Precautions for installation 4 1 ...
Страница 30: ......
Страница 35: ......
Страница 53: ......
Страница 75: ......
Страница 154: ......
Страница 196: ......
Страница 203: ...Chapter 10 Troubleshooting This chapter describes the troubleshooting methods ...
Страница 204: ......
Страница 211: ......
Страница 219: ......
Страница 229: ......
Страница 289: ...Appendix Appendix A Appendix A 1 ...
Страница 290: ......
Страница 292: ...Appendix Appendix 2 ...