Chapter 8 List of Data Settings
8 - 2
Code
Function name
Monitored data or setting
Default
Setting
during
operation
(allowed or
not)
Change
during
operation
(allowed or
not)
Page
d025
User monitor 0
-2147483647 to 2147483647 (upper 4 digits including “-“)
−
−
−
4-5
d026
User monitor 1
-2147483647 to 2147483647 (upper 4 digits including “-“)
−
−
−
d027
User monitor 2
-2147483647 to 2147483647 (upper 4 digits including “-“)
−
−
−
d028
Pulse counter
0 to 2147483647 (upper 4 digits)
−
−
−
4-5
d080
Trip Counter
0. to 9999., 1000 to 6553 (10000 to 65530) (times)
−
−
−
4-5
d081
Trip monitoring 1
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
−
−
−
4-5
d082
Trip monitoring 2
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
−
−
−
d083
Trip monitoring 3
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
−
−
−
d084
Trip monitoring 4
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
−
−
−
d085
Trip monitoring 5
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
−
−
−
d086
Trip monitoring 6
Factor, frequency (Hz), current (A), voltage across P-N (V),
running time (hours), power-on time (hours)
−
−
−
d090
Programming error monitoring
Warning code
−
−
−
4-5
d102
DC voltage monitoring
0.0 to 999.9 (V)
−
−
−
4-5
d103
BRD load factor monitoring
0.0 to 100.0 (%)
−
−
−
4-6
d104
Electronic thermal overload
monitoring
0.0 to 100.0 (%)
−
−
−
4-6
8.3 Function Mode
Code
Function name
Monitored data or setting
Default
Setting
during
operation
(allowed or
not)
Change
during
operation
(allowed or
not)
Page
_FF
F001 Output
frequency
setting
0.0, "start frequency" to "maximum frequency"
(or maximum frequency, 2nd/3rd motors) (Hz)
0.0 to 100.0 (when PID function is enabled)
0.00
{
{
4-7
F002
Acceleration (1) time setting
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F202
Acceleration (1) time setting,
2nd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F302
Acceleration (1) time setting,
3rd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F003
Deceleration (1) time setting
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F203
Deceleration time setting,
2nd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F303
Deceleration time setting,
3rd motor
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
30.00
{
{
4-10
F004
Keypad Run key routing
00 (forward rotation), 01 (reverse rotation)
00
¯
¯
4-7
Содержание L700 Series
Страница 16: ... Memo ...
Страница 20: ... Memo ...
Страница 22: ... Memo ...
Страница 46: ... Memo ...
Страница 60: ... Memo ...
Страница 62: ... Memo ...
Страница 212: ... Memo ...
Страница 222: ... Memo ...
Страница 224: ... Memo ...
Страница 232: ... Memo ...
Страница 237: ...Chapter 7 Specifications 7 5 L700 300 LFF HFF L700 450 550 LFF HFF 750 HFF 5 Cable hole φ25 5 Cable hole φ41 ...
Страница 238: ...Chapter 7 Specifications 7 6 L700 750 LFF 6 Cable hole φ41 ...
Страница 239: ...Chapter 7 Specifications 7 7 L700 900 to 1100HFF L700 1320 to 1600HFF ...
Страница 240: ... Memo ...
Страница 242: ... Memo ...
Страница 258: ... Memo ...