Chapter 4 Explanation of Functions
4 - 73
4.2.75 Reverse rotation signal (RVR)
The inverter continues to output the forward rotation (RVR)
signal while it is driving the motor for reverse operation.
The RVR signal is turned off while the inverter is driving the motor for forward operation or stopping the
motor.
Item
Function code
Data or range of data
Description
Terminal function
C021 to C025
52
RVR: Reverse rotation signal
Alarm relay terminal function
C026
4.2.76 Major failure signal (MJA)
The inverter outputs the major failure (MJA) signal in addition to
an alarm signal when it trips because of one of the errors listed
below.
(This signal function applies to the tripping caused by hardware.)
No.
Error code
Description
1 E10.*
CT
error
2 E11.*
CPU
error
3 E14.*
Ground-fault
protection
4
E20.*
Temperature error due to cooling-fan fault
5
E23.*
Gate array communication error
6
E25.*
Main circuit error
Item
Function code
Data or range of data
Description
Terminal function
C021 to C025
53
MJA: Major failure signal
Alarm relay terminal function
C026
C021 to C025: Terminal [11] to [15] functions
C026: Alarm relay terminal function
Related code
Output frequency (Hz)
Forward rotation signal
Reverse rotation signal
C021 to C025: Terminal [11] to [15] functions
C026: Alarm relay terminal function
Related code
Содержание L700 Series
Страница 16: ... Memo ...
Страница 20: ... Memo ...
Страница 22: ... Memo ...
Страница 46: ... Memo ...
Страница 60: ... Memo ...
Страница 62: ... Memo ...
Страница 212: ... Memo ...
Страница 222: ... Memo ...
Страница 224: ... Memo ...
Страница 232: ... Memo ...
Страница 237: ...Chapter 7 Specifications 7 5 L700 300 LFF HFF L700 450 550 LFF HFF 750 HFF 5 Cable hole φ25 5 Cable hole φ41 ...
Страница 238: ...Chapter 7 Specifications 7 6 L700 750 LFF 6 Cable hole φ41 ...
Страница 239: ...Chapter 7 Specifications 7 7 L700 900 to 1100HFF L700 1320 to 1600HFF ...
Страница 240: ... Memo ...
Страница 242: ... Memo ...
Страница 258: ... Memo ...