403
11.3.3
Normal Pulse Output
Sample Setup Procedure for Normal Pulse Output: Figure 11-4 shows a sample procedure for
setting up normal pulse output.
Select TGR functions
[1]
Set TGRA value
Set counting operation
Select interrupt request
Set initial output data
Enable pulse output
Select output trigger
Set next pulse
output data
Start counter
Set next pulse
output data
Normal PPG output
No
Yes
TPU setup
Port and
PPG setup
TPU setup
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
Compare match?
[1] Set TIOR to make TGRA an output
compare register (with output
disabled)
[2] Set the PPG output trigger period
[3] Select the counter clock source
with bits TPSC2 to TPSC0 in TCR.
Select the counter clear source
with bits CCLR1 and CCLR0.
[4] Enable the TGIA interrupt in TIER.
The DTC can also be set up to
transfer data to NDR.
[5] Set the initial output values in
PODR.
[6] Set the DDR and NDER bits for the
pins to be used for pulse output to 1.
[7] Select the TPU compare match
event to be used as the output
trigger in PCR.
[8] Set the next pulse output values in
NDR.
[9] Set the CST bit in TSTR to 1 to
start the TCNT counter.
[10] At each TGIA interrupt, set the next
output values in NDR.
Figure 11-4 Setup Procedure for Normal Pulse Output (Example)
Содержание H8S/2645
Страница 4: ......
Страница 16: ......
Страница 58: ...26 ...
Страница 110: ...78 ...
Страница 120: ...88 ...
Страница 132: ...100 ...
Страница 160: ...128 ...
Страница 172: ...140 ...
Страница 235: ...203 Transfer SAR or DAR DAR or SAR Block area First block Nth block Figure 8 8 Memory Mapping in Block Transfer Mode ...
Страница 418: ...386 ...
Страница 444: ...412 ...
Страница 530: ...498 ...
Страница 562: ...530 ...
Страница 642: ...610 ...
Страница 662: ...630 ...
Страница 688: ...656 ...
Страница 756: ...724 ...
Страница 784: ...752 ...
Страница 812: ...780 ...
Страница 837: ...805 A 2 Instruction Codes Table A 2 shows the instruction codes ...
Страница 1152: ...1120 ...