8. Troubleshooting
274
SMGB0079 rev.0 - 01/2013
Protection control code on 7-segment display
1
Protection control code is displayed on 7-segment when a protection control is activated.
2
Protection control code is displayed while function is working, and goes out when released.
3
When several protection control are activated, code number with higher priority will be indicated (see below for the
priority order).
a.
Higher priority is given to protection control related to frequency control than the other. Priority order:
High-pressure increase protection
Over current protection
Cold draft protection
b.
In relation to retry control, the latest retrial will be indicated unless a protection control related to frequency control
is indicated.
RAS-(2-2.5)HVNP / RAS-3HVNC
Priority
Protection control
Code
1
Low-Pressure Ratio Control at Cooling Operation
p00
2
High-pressure ratio control at heating operation
p01
3
High-pressure rise protection
p02
4
Current protection
p03
5
Inverter fin temperature rise prevention
P04
6
Discharge gas temperature rise protection
p05
7
Unbalance Power Source Detecting
p09
8
Demand current control
p0A
9
Low-Pressure Decrease Protection
p0b
RAS-(3-12)H(V)N(P/C)(E)
Priority
Protection control
Code
1
Pressure ratio control
p01
2
High-pressure rise protection
p02
3
Current protection
p03
4
Inverter fin temperature rise prevention
P04
5
Discharge gas temperature rise protection
p05
6
Demand current control (running current limit control)
p0A
7
High pressure decrease protection (only Premium series)
p09
N O T E
The protection control code being indicated on 7-segment display is changed to an alarm code when the abnormal
operation occurs. Also, the same alarm code is indicated on the remote control switch.
Содержание EV-1.5N1
Страница 2: ......
Страница 4: ... II ...
Страница 26: ......
Страница 100: ......
Страница 123: ...4 Electrical wiring 109 SMGB0079 rev 0 01 2013 4 4 7 2 RAS 3HVNPE 1 230V 50Hz U Surface V Surface W Surface XEK01261_0 ...
Страница 124: ...4 Electrical wiring 110 SMGB0079 rev 0 01 2013 4 7 3 RAS 4 6 HVNPE 1 230V 50Hz U Surface V Surface W Surface XEK01262_0 ...
Страница 128: ...4 Electrical wiring 114 SMGB0079 rev 0 01 2013 4 7 7 RAS 8 10 HN P C E 3N 400V 50Hz XEK01288_0 ...
Страница 129: ...4 Electrical wiring 115 SMGB0079 rev 0 01 2013 4 4 7 8 RAS 12HNP 3N 400V 50Hz Preliminary data 317S136064 ...
Страница 130: ...4 Electrical wiring 116 SMGB0079 rev 0 01 2013 4 7 9 RAS 12HNC 3N 400V 50Hz Preliminary data 317S136071 ...
Страница 144: ...5 Control System 130 SMGB0079 rev 0 01 2013 5 4 2 Dry operation Continues in the next page ...
Страница 148: ...5 Control System 134 SMGB0079 rev 0 01 2013 5 4 4 Automatic cooling and heating operation ...
Страница 158: ......
Страница 196: ......
Страница 212: ...8 Troubleshooting 198 SMGB0079 rev 0 01 2013 ...
Страница 215: ...8 Troubleshooting 201 SMGB0079 rev 0 01 2013 8 ...
Страница 323: ...9 Spare parts 309 SMGB0079 rev 0 01 2013 9 RAS 8 10 HNCE Spare Parts Document EPN 201211B ...
Страница 324: ...9 Spare parts 310 SMGB0079 rev 0 01 2013 9 6 2 Electrical parts Spare Parts Document EPN 201211B ...
Страница 332: ......
Страница 452: ......
Страница 479: ......