3. Piping work and refrigerant charge
80
SMGB0079 rev.0 - 01/2013
3.6.3 Permissible range for existing Air-Conditioning Pipes
(Pipe length in the case of “without cleaning process”.
IVX Premium series
Liquid
Ø6.35
Ø9.52
Ø12.70
Ø15.88
Thickness (mm)
0.8
0.8
0.8
1.0
Gas
Ø9.52
Ø12.70
Ø15.88
Ø19.05
Ø12.70
Ø15.88
Ø19.05
Ø22.20
Ø25.40
Ø15.88
Ø19.05
Ø22.20
Ø25.40
Ø28.58
Ø22.20
Ø25.40
Ø28.58
Thickness (mm)
0.8
0.8
1.0
1.0
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Material Soft-
annealed
x
x
x
x
x
x
x
x
x
Material Draw
x
x
x
x
x
x
x
x
x
x
x
Performance
capacity
(m)
2 HP
15
(1)
50
30
-
15
(3)
15
(3)
-
-
-
-
-
-
-
-
-
-
-
2.5 HP
-
50
30
-
20
(3)
20
(3)
-
-
-
-
-
-
-
-
-
-
-
3 HP
-
30
(1)(2)
30
(2)
-
30
(1)
50
-
-
-
-
-
-
-
-
-
-
-
4 - 5 - 6
HP
-
-
5
(2)
5
(2)
40
(1)
50
50
(4)
-
-
30
(3)
30
(3)
(4)
-
-
-
-
-
-
8 HP
-
-
-
-
-
-
50
(1)(4)
50
(1)
50
-
50
(1)(3)(4)
50
(1)(3)
50
(3)
-
50
(1)(3)
50
(3)
-
10 - 12 HP
-
-
-
-
-
-
-
-
-
-
-
50
(1)
50
50
50
(1)(3)
50
(3)
50
(3)
(1).Reducing gas pipe size will lower cooling capacity due to larger pressure loss in gas piping and narrow operation range.
(2).Reducing liquid pipe size will narrow operation range due to indoor unit relation with expansion valve capacity.
(3).Increasing liquid pipe size will require additional refrigerant charge.
(4).When using Ø 19.05 gas pipe (soft-annealed), please switch ON DSW2-4# in the Outdoor Unit PCB.
Standard
IVX Standard series
Liquid
Ø6.35
Ø9.52
Ø12.70
Ø15.88
Thickness (mm)
0.8
0.8
0.8
1.0
Gas
Ø9.52
Ø12.70
Ø15.88
Ø19.05
Ø12.70
Ø15.88
Ø19.05
Ø22.20
Ø25.40
Ø15.88
Ø19.05
Ø22.20
Ø25.40
Ø28.58
Ø22.20
Ø25.40
Ø28.58
Thickness (mm)
0.8
0.8
1.0
1.0
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Material Soft-
annealed
x
x
x
x
x
x
x
x
x
Material Draw
x
x
x
x
x
x
x
x
x
x
x
Performance
capacity
(m)
3 HP
-
30
(1)(2)
30
(2)
-
30
(1)
50
-
-
-
-
-
-
-
-
-
-
-
4 HP
-
-
5
(2)
5
(2)
40
(1)
50
50
(4)
30
(3)
30
(3)(4)
-
-
-
-
-
-
5 - 6 HP
-
-
5
(2)
5
(2)
40
(1)
50
50
(4)
30
(3)
30
(3)(4)
-
-
-
-
-
-
8 HP
-
-
-
-
-
-
50
(1)(4)
50
(1)
50
-
50
(1)(3)(4)
50
(1)(3)
50
(3)
-
50
(1)(3)
50
(3)
-
10 - 12 HP
-
-
-
-
-
-
-
-
-
-
-
50
(1)
50
50
50
(1)(3)
50
(3)
50
(3)
(1).Reducing gas pipe size will lower cooling capacity due to larger pressure loss in gas piping and narrow operation range.
(2).Reducing liquid pipe size will narrow operation range due to indoor unit relation with expansion valve capacity.
(3).Increasing liquid pipe size will require additional refrigerant charge.
(4).When using Ø 19.05 gas pipe (soft.annealed), please switch ON DSW2-4# in the Outdoor Unit PCB.
Standard
Содержание EV-1.5N1
Страница 2: ......
Страница 4: ... II ...
Страница 26: ......
Страница 100: ......
Страница 123: ...4 Electrical wiring 109 SMGB0079 rev 0 01 2013 4 4 7 2 RAS 3HVNPE 1 230V 50Hz U Surface V Surface W Surface XEK01261_0 ...
Страница 124: ...4 Electrical wiring 110 SMGB0079 rev 0 01 2013 4 7 3 RAS 4 6 HVNPE 1 230V 50Hz U Surface V Surface W Surface XEK01262_0 ...
Страница 128: ...4 Electrical wiring 114 SMGB0079 rev 0 01 2013 4 7 7 RAS 8 10 HN P C E 3N 400V 50Hz XEK01288_0 ...
Страница 129: ...4 Electrical wiring 115 SMGB0079 rev 0 01 2013 4 4 7 8 RAS 12HNP 3N 400V 50Hz Preliminary data 317S136064 ...
Страница 130: ...4 Electrical wiring 116 SMGB0079 rev 0 01 2013 4 7 9 RAS 12HNC 3N 400V 50Hz Preliminary data 317S136071 ...
Страница 144: ...5 Control System 130 SMGB0079 rev 0 01 2013 5 4 2 Dry operation Continues in the next page ...
Страница 148: ...5 Control System 134 SMGB0079 rev 0 01 2013 5 4 4 Automatic cooling and heating operation ...
Страница 158: ......
Страница 196: ......
Страница 212: ...8 Troubleshooting 198 SMGB0079 rev 0 01 2013 ...
Страница 215: ...8 Troubleshooting 201 SMGB0079 rev 0 01 2013 8 ...
Страница 323: ...9 Spare parts 309 SMGB0079 rev 0 01 2013 9 RAS 8 10 HNCE Spare Parts Document EPN 201211B ...
Страница 324: ...9 Spare parts 310 SMGB0079 rev 0 01 2013 9 6 2 Electrical parts Spare Parts Document EPN 201211B ...
Страница 332: ......
Страница 452: ......
Страница 479: ......