4. Electrical wiring
105
SMGB0079 rev.0 - 01/2013
4
• Connection with one main line and with the branch lines for the units.
A
A: Outdoor units.
B: Indoor units.
C A U T I O N
•
The maximum number of units than can be connected is 64 outdoor units and 160 indoor units (including Uto-
pia and/or Set Free, Mini Set-free).
•
Do not install the wiring in a loop.
•
If the H-LINK II system is not used when carrying out the electrical wiring as shown above, it must be used
once the wiring of the instrument is completed. The DIP switches must therefore be set as specified in the DIP
switches on the PCB.
2. Using the H-LINK II system for air conditioning systems with a central control device (CSNET WEB or PSC-
A64S)
• If the central control device is used when carrying out electrical wiring, the CS-NET WEB can be connected at any point
of the H-LINK II wiring.
A
A: Outdoor units.
B: Indoor units.
• If the central control device is not used when electrical wiring is carried out, you must connect the H-LINK II wiring to all
the systems. The easiest method is usually to connect the outdoor units.
N O T E
For CSNET WEB 2.0 the limitations are those corresponding to H-LINK.
Содержание EV-1.5N1
Страница 2: ......
Страница 4: ... II ...
Страница 26: ......
Страница 100: ......
Страница 123: ...4 Electrical wiring 109 SMGB0079 rev 0 01 2013 4 4 7 2 RAS 3HVNPE 1 230V 50Hz U Surface V Surface W Surface XEK01261_0 ...
Страница 124: ...4 Electrical wiring 110 SMGB0079 rev 0 01 2013 4 7 3 RAS 4 6 HVNPE 1 230V 50Hz U Surface V Surface W Surface XEK01262_0 ...
Страница 128: ...4 Electrical wiring 114 SMGB0079 rev 0 01 2013 4 7 7 RAS 8 10 HN P C E 3N 400V 50Hz XEK01288_0 ...
Страница 129: ...4 Electrical wiring 115 SMGB0079 rev 0 01 2013 4 4 7 8 RAS 12HNP 3N 400V 50Hz Preliminary data 317S136064 ...
Страница 130: ...4 Electrical wiring 116 SMGB0079 rev 0 01 2013 4 7 9 RAS 12HNC 3N 400V 50Hz Preliminary data 317S136071 ...
Страница 144: ...5 Control System 130 SMGB0079 rev 0 01 2013 5 4 2 Dry operation Continues in the next page ...
Страница 148: ...5 Control System 134 SMGB0079 rev 0 01 2013 5 4 4 Automatic cooling and heating operation ...
Страница 158: ......
Страница 196: ......
Страница 212: ...8 Troubleshooting 198 SMGB0079 rev 0 01 2013 ...
Страница 215: ...8 Troubleshooting 201 SMGB0079 rev 0 01 2013 8 ...
Страница 323: ...9 Spare parts 309 SMGB0079 rev 0 01 2013 9 RAS 8 10 HNCE Spare Parts Document EPN 201211B ...
Страница 324: ...9 Spare parts 310 SMGB0079 rev 0 01 2013 9 6 2 Electrical parts Spare Parts Document EPN 201211B ...
Страница 332: ......
Страница 452: ......
Страница 479: ......