9.6 Message List
131
9
Message
Data Formats
[ ]: Response data.
Description
Ref
page
Trigger
:INITiate:CONTinuous
1/ 0/ ON/ OFF
Sets and queries continuous
measurement.
:INITiate:CONTinuous?
[ON/ OFF]
:INITiate[:IMMediate]
Trigger Wait Setting
:TRIGger:SOURce
IMMediate/ EXTernal
Sets and queries the trigger source.
:TRIGger:SOURce?
[IMMEDIATE/ EXTERNAL]
:TRIGger:DELay1
0 to 0.100
Sets and queries Trigger Delay 1 time.
:TRIGger:DELay1?
[0 to 0.100]
:TRIGger:EDGE
RISE/ FALL
Sets and queries trigger (falling (ON)/
rising (OFF)) logic.
:TRIGger:EDGE?
Range-Specific Resistance Measurement Settings
(Low Power Resistance Measurement Settings)
:LPResistance:DELay2
<Range>,< Delay 2 time>
Sets and queries Delay 2 time.
:LPResistance:DELay2?
<Range>
[0 to 0.100]
:LPResistance:NPLCycles
<Range>,<Speed>,
<Integration time (NPLC)>
Sets and queries integration time
(multiples of power line cycles).
:LPResistance:NPLCycles?
<Range>,<Speed> [0.01
to 6]
:LPResistance:APERture
<Range>,<Speed>,
<integration time (s)>
Sets and queries integration time
(in seconds).
:LPResistance:APERture?
<Range>,<Speed>
[0.0001 to 0.1]
:LPResistance:CIMProve
<Range>,<OFF/ HOLD/
PULSe>
Sets and queries contact improver
operating mode.
:LPResistance:CIMProve?
<Range>
[OFF/ HOLD/ PULSE]
:LPResistance:CIMProve:LEVel
<Range>,<Level>
Sets and queries contact improver
level.
:LPResistance:CIMProve:LEVel?
<Range>
[L1/ L2/ L3/ L4]
:LPResistance:CURRent
<Range>,<PULSe/CON-
Tinuous>
Sets and queries measurement
current mode.
:LPResistance:CURRent?
<Range>
[PULSE/ CONTINUOUS]
:LPResistance:CONTactcheck
<Range>,<1/ 0/ ON/ OFF>
Sets and queries contact check
operation.
:LPResistance:CONTactcheck?
<Range>
[ON/ OFF]
:LPResistance:CONTactcheck:LEVel
<Range>,<Level>
Sets and queries contact check
threshold.
:LPResistance:CONTactcheck:LEV--
el?
<Range>
[L1/ L2/ L3/ L4/ L5/ L6/ L7]
:LPResistance:VMONitor
<Range>,<1/ 0/ ON/ OFF>
Sets and queries voltage level monitor
level.
:LPResistance:VMONitor?
<Range>
[ON/ OFF]
:LPResistance:VMONitor:LEVel
<Range>,<Level>
Sets and queries voltage level monitor
level.
:LPResistance:VMONitor:LEVel?
<Range>
[L1/ L2/ L3]
Notes:
•
< >: indicates contents of the data portion.
•
[ ]: indicates Response data.
•
<Range>
For :RESistance commands: RNG100MIL/ RNG1000MIL/ RNG3/ RNG10/ RNG100/ RNG300/ RNG1000/ RNG10K/
RNG30K/ RNG100K/ RNG300K/ RNG1000K/ RNG3MEG/ RNG10MEG/ RNG30MEG/ RNG100MEG
For :LPResistance commands: RNG1000MIL/ RNG3/ RNG10/ RNG100/ RNG300/ RNG1000
Содержание RM3542-50
Страница 1: ......
Страница 2: ......
Страница 6: ...Table of Contents iv...
Страница 26: ...1 3 Screen Organization 20...
Страница 32: ...2 3 Turning the Power On and Off 26...
Страница 48: ...3 8 Confirming Faulty Measurements 42...
Страница 72: ...4 14 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 66...
Страница 84: ...5 7 Initializing Reset 78...
Страница 94: ...6 4 Auto Exporting Measurement Values at End of Measurement Data Output Function 88...
Страница 206: ...11 4 Disposing of the Instrument 200...
Страница 216: ...Appendix 5 Dimensional diagram A10 Appendix 5 Dimensional diagram Unit mm...
Страница 230: ...Index Index 4...
Страница 231: ...HIOKI E E CORPORATION...
Страница 232: ......
Страница 233: ......
Страница 234: ......