![Hioki RM3542-50 Скачать руководство пользователя страница 197](http://html1.mh-extra.com/html/hioki/rm3542-50/rm3542-50_instruction-manual_2137361197.webp)
Chapter 10 Specifications
191
10
Printer
Printing Contents
Measured data (PRINT signal input), Total data count, Mean, Minimum value (sample
No.), Maximum value (sample No.), Standard deviation of sample, Population standard
deviation, and Process capability indices,
IN count, Hi count, Lo count, OvrRng count, No. of Measurement faults
Printing method
Default setting
NORMAL, (100), (ALL), (3/L)
Setting Functions
NORMAL/SAMPL
Number of samplings 1 to 999 (SAMPL only)
Printing condition
ALL/IN (SAMPL only)
Number of characters 1/L / 3/L (SAMPL only)
Communications
Communications method Asynchronous RS-232C
Transmission speed
9,600bps
Data length
8 bits
Stop bit
1 bit
Parity bit
None
Delimiter
Transmit CR+LF, Receive CR/ CR+LF
Handshake
No X-flow, no hardware flow
GP-IB interface (RM3542-51 only)
Communication contents
Remote control
Interface
Functions
SH1
All Source Handshake functions are supported.
AH1
All Acceptor Handshake functions are supported.
T6
Basic talker functions are supported.
Serial poll function are supported.
No talk-only mode
The talker cancel function with MLA (My Listen Address) is supported.
L4
Basic listener functions are supported.
No listen-only mode.
The listener cancel function with MTA (My Talk Address) is supported.
SR1
All Service Request functions are supported.
RL1
All Remote/Local functions are supported.
PP0
No Parallel Poll function
DC1
All Device Clear functions are supported.
DT1
All Device Trigger functions are supported.
C0
No Controller function
Miscellaneous
Conforms to IEEE 488.1
Settings Monitor terminal (SET MONITOR)
Connector
Male 9-pin D-sub, with #4-40 attachment screws
Connection cable
Crossover
Содержание RM3542-50
Страница 1: ......
Страница 2: ......
Страница 6: ...Table of Contents iv...
Страница 26: ...1 3 Screen Organization 20...
Страница 32: ...2 3 Turning the Power On and Off 26...
Страница 48: ...3 8 Confirming Faulty Measurements 42...
Страница 72: ...4 14 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 66...
Страница 84: ...5 7 Initializing Reset 78...
Страница 94: ...6 4 Auto Exporting Measurement Values at End of Measurement Data Output Function 88...
Страница 206: ...11 4 Disposing of the Instrument 200...
Страница 216: ...Appendix 5 Dimensional diagram A10 Appendix 5 Dimensional diagram Unit mm...
Страница 230: ...Index Index 4...
Страница 231: ...HIOKI E E CORPORATION...
Страница 232: ......
Страница 233: ......
Страница 234: ......