Appendix 8 Table of Comparison Commands ADEX AX-162D / for this instrument
A
14
Appendix 8 Table of Comparison Commands
ADEX AX-162D / for this instrument
Description
Model AX-162D (Original mode)
Model RM3542A
Command
Query
Data
Command
Query
Data
Measure-
ment mode
setting
M
m
-
m
= 0/
D (% mode)/1/
R (R mode)
:CALCulate:LIMit:MODE
m
-
m
= REF%
(REF mode)/
ABS (ABS
mode)
M?
XANS1,M
m
:CALCulate:LIMit:MODE?
m
Measure-
ment range
setting
RNG
r
-
r
= 0 to 9
:RESistance:RANGe
r
-
r
= 0 to
120E+6
RNG?
XANS1,RNG
r
:RESistance:RANGe?
r
Reference
resistor set-
ting
RS
float
-
float
=
500E-5 to
4
:CALCulate:LIMit:REFer-
ence
float
-
float
= 0 to
120.000E+6
RS?
XANS1,RS
float
:CALCulate:LIMit:REFer-
ence?
float
% mode
upper and
lower
limit values
setting
LH
float1
-
float1
=
-9999E-2 to
9999E-2
:CALCulate:LIMit:PER--
Cent
float1,float2
:CALCulate:LIMit:PER--
Cent?
float1,
float2
float1
=
-99.990 to
99.990
float2
=
-99.990 to
99.990
LH?
XANS1,LH
float1
LL
float2
-
float2
=
-9999E-2 to
9999E-2
LL?
XANS1,LL
float2
R mode
upper and
lower
limit values
setting
LH
float1
-
float1
=
00001E-5 to
4
:CALCulate:LIMit:ABS
float1,float2
:CALCulate:LIMit:ABS?
-
float1,
float2
float1
= 0 to
120.000E+6
float2
= 0 to
120.000E+6
LH?
XANS1,LH
float1
LL
float2
-
float2
=
00001E-5 to
4
LL?
XANS1,LL
float2
Shift range
up
command
SFTRNGU
-
(Multiple commands)
r1
= r x 10
:RESistance:RANGe?
r
:RESistance:RANGe
r1
-
Shift range
down
command
SFTRNGD
-
(Multiple commands)
r1
= r/10
:RESistance:RANGe?
r
:RESistance:RANGe
r1
-
Measure-
ment speed
setting
S
s
-
s
= 0 (SLOW
mode)/ 1
(FAST mode)
:SPEEd
s
-
s
= FAST/
MEDium/
SLOW
S?
XANS1,S
s
:SPEEd?
s
Trigger
E
-
∗
TRG
-
Note: This instrument cannot accept continuous commands (a delimiter is necessary between multiple commands).
Содержание RM3542-50
Страница 1: ......
Страница 2: ......
Страница 6: ...Table of Contents iv...
Страница 26: ...1 3 Screen Organization 20...
Страница 32: ...2 3 Turning the Power On and Off 26...
Страница 48: ...3 8 Confirming Faulty Measurements 42...
Страница 72: ...4 14 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 66...
Страница 84: ...5 7 Initializing Reset 78...
Страница 94: ...6 4 Auto Exporting Measurement Values at End of Measurement Data Output Function 88...
Страница 206: ...11 4 Disposing of the Instrument 200...
Страница 216: ...Appendix 5 Dimensional diagram A10 Appendix 5 Dimensional diagram Unit mm...
Страница 230: ...Index Index 4...
Страница 231: ...HIOKI E E CORPORATION...
Страница 232: ......
Страница 233: ......
Страница 234: ......