3.7 Setting the Auto Save Function
────────────────────────────────────────────────────
Function
display
Meaning
: When [Make directory] is set to [NONE], auto-
save is cancelled when the storage
media is full, or when the directory's file count
exceeds 5000.
When [Make directory] is set to [EXIST], a new
directory is created each time the current
directory's file count exceeds 5000, until the
storage media fills up, causing auto-save to
cancel.
: When the media becomes full, old files are
deleted to make room for automatic storage.
When 1 Block Save is selected with the Binary
Format, the file extension 'MEM' or 'REC' are
deleted. If sequential save is selected, or if the
saving data is 'R&M', this setting is invalid.
When All Block Save is selected with the
Binary Format, this operation is disabled.
With the text format selected, files with the
extension 'TXT' are deleted.
Function
display
Meaning
: 1 block save of recorder data
: 1 block save of memory data
: All block save both recorder and memory data
NOTE
9. When Media is selected, the Storage method item appears.
10. Set the data save area.
Select to save all of the waveform data or only the data between cursors A
and B.
11. Select the item to be stored.
File names consist of 8 characters. With auto-save, since numbers are attached
to the end of file names, long file names are truncated when this number is
appended to the end of the file name.
When automatic storage is selected for both recorder and memory data,
automatic storage is activated (an index file is created). If only recorder or
memory is set for storage, 1 block save is performed.
When auto-save is enabled, the storage channel cannot be selected. Data for the
channel for which the waveform is displayed is saved. For details on auto saving
file name,
see to Quick Start Section 10.7
.
When the recording length of the recorder is set to "CONT.", the auto-saving
cannot be made a setting.
When cursor A and B are enabled, their setting will be preferred.
If additional recording is enabled, only newly acquired waveforms are saved.
Even when A and B cursors appear on the screen, no partial save is performed.
The same media is used for both the recorder and memory. Separate media
cannot be selected.
The directory and the number of files that can be stored in the directory are
limited. For details,
see Quick Start Section 10.7
.
During automatic storage, if the STOP key is pressed to interrupt measurement,
waveforms taken prior to the interruption are stored automatically.
Do not use the s, =, and [,] in a file name. A file containing any of
these symbols in its file name cannot be processed under Windows 2000 or XP.
Содержание MEMORY HiCORDER 8855
Страница 2: ......
Страница 20: ...xii Chapter Summary...
Страница 21: ...1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Chapter 1 Product Overview...
Страница 28: ...8 1 2 Identification of Controls and Indicators...
Страница 113: ...93 4 8 FFT Analysis Function Stored waveform 1 1 octave analysis 1 3 octave analysis Example Octave analysis waveforms...
Страница 116: ...96 4 8 FFT Analysis Function...
Страница 117: ...97 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Chapter 5 Input Channel Settings...
Страница 177: ...157 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Chapter 8 Search Function...
Страница 186: ...166 8 6 Moving Cursors to the Search Points...
Страница 205: ...185 10 5 Example of Printer Output Printing the List MEM Example...
Страница 263: ......
Страница 264: ......