Device Drawings
46/223
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM46EN | Revision 46 | English | 2015-12 | Relelased | Public
© Hilscher, 2008-2015
Note:
*Device supports Auto Crossover Function. Note also: With loaded EtherCAT Ma-
ster firmware only the RJ45 channel 0 can be used, channel 1 is deactivated. Beginning
with EtherCAT Master firmware V3 channel 1 can be reactivated if redundancy is active-
ted. For Open Modbus/TCP with V2.3.4.0 and higher both RJ45 channels can be used.
For the
SYNC
pin assignment of the SYNC Connector refer to section
Pin Assignment
SYNC Connector, X51
(CIFX 50 50E 70E)
on page 112. Device drawings of earlier
device revisions without rotary switch slot number (card ID) are included in the user
manual for PC cards cifX Real-Time Ethernet up to manual rev. 32.
The figure below shows the front plate of the PC cards CIFX 50-RE, CIFX
50-RE\ET, CIFX 50E-RE or CIFX 50E-RE\ET
:
$
Rotary Switch Slot Number (Card ID)*
The figure shows the rotary switch in position 1. Refer also to
section
Rotary Switch for Slot Number (Card ID)
, page 110.
%
System LED
(yellow/green)
&
Communication Status LED 0
* (red/green)
'
Communication Status LED 1
* (red/green),
(*Designation and meaning depends by protocol)
Refer also to chapter
LED Descriptions
, page 80.
(
Ethernet Interface Channel 0
1
2
3
4
5
6
SYS
COM0
0
2
3
4
5
6
7 8
9
1
COM1
)
Ethernet Interface Channel 1
Refer also to section
Ethernet Interface
, page 105.
Figure 4: Front Plate for CIFX 50-RE, CIFX 50-RE\ET, CIFX 50E-RE or CIFX 50E-RE\ET
*From hardware revision 3 (for CIFX 50-RE), 1 (for CIFX 50-RE\ET),4 (for
CIFX 50E-RE) or 1 (for CIFX 50E-RE\ET) on, the
Rotary Switch
Slot
Number (Card ID)
is provided.