Introduction
17/223
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM46EN | Revision 46 | English | 2015-12 | Relelased | Public
© Hilscher, 2008-2015
1.2.4
Device Description Files PC Cards cifX
The Communication Solutions DVD
EDS
directory includes the device
description files for the PC Cards cifX. The device description file is
required to configure the used Master device. The systems Open
Modbus/TCP, AS-Interface, PROFIBUS MPI and VARAN do not use device
description files.
PC Cards cifX
System
File Name of the Device Description File
For the EtherCAT Slave Firmware V2.5:
Hilscher cifX RE ECS V2.2.x.xml
(or with extension DDF)
EtherCAT Slave
For the EtherCAT Slave Firmware with V4.2.1.0
the
Hilscher CIFX RE ECS V4.2.X.xml
is provided.
Note!
If the XML file
Hilscher cifX RE ECS V2.2.x.xml
is used/re-installed, the firmware
must be used/re-installed at the Version
2.5.x
.
EtherNet/IP Adapter (Slave)
HILSCHER CIFX-RE EIS V1.1.EDS
EtherNet/IP Scanner (Master)
HILSCHER CIFX-RE EIM V1.0.eds
Note!
The description files for the EtherNet/IP Master device is needed, when an
additional EtherNet/IP Master device shall communicate to a Hilscher EtherNet/IP
Master device via EtherNet/IP.
POWERLINK Controlled
Node/Slave
00000044_CIFX RE PLS.xdd
For the PROFINET IO Device Firmware V3.4:
GSDML-V2.3-HILSCHER-CIFX RE PNS-20130225.xml
PROFINET IO-Device
For the PROFINET IO Device Firmware with V3.5.13.1
the
GSDML-V2.3-HILSCHER-CIFX RE PNS-20130301.xml
is
provided.
CIFX 50-RE,
CIFX 50-RE\ET,
CIFX 50E-RE,
CIFX 50E-RE\ET,
CIFX 70E-RE,
CIFX 70E-RE\MR,
CIFX 100EH-
RE\CUBE
sercos Slave
Hilscher CIFX RE S3S FixCFG FSPIO Default.xml,
Hilscher CIFX RE S3S VarCFG FSPDrive.xml
Note!
If you use a sercos Master which is using SDDML files for configuration, and one of
the defaults for vendor code, device ID, input data size or output data size was changed,
then you have to export a new updated SDDML file from SYCON.net and import this
SDDML file into the configuration software for the sercos Master.
CIFX 50-DP,
CIFX 50-2DP,
CIFX 50E-DP,
CIFX 70E-DP,
CIFX 70E-DP\MR
PROFIBUS DP Slave
HIL_0B69.GSD
CIFX 50-2DP\CO
PROFIBUS DP Slave
HIL_0B69.GSD
CANopen
Slave
CIFX CO COS.eds
CIFX 50-2DP\DN
PROFIBUS DP Slave
HIL_0B69.GSD
DeviceNet
Slave
CIFX_DN_DNS.EDS
CIFX 50-CO,
CIFX 50-2CO,
CIFX 50E-CO,
CIFX 70E-CO,
CIFX 70E-CO\MR
CANopen Slave
CIFX CO COS.eds
CIFX 50-2CO\DN
CANopen Slave
CIFX CO COS.eds
DeviceNet
Slave
CIFX_DN_DNS.EDS
CIFX 50-DN,
CIFX 50-2DN,
CIFX 50E-DN,
CIFX 70E-DN,
CIFX 70E-DN\MR
DeviceNet Slave
CIFX_DN_DNS.EDS
CIFX 50-CC,
CIFX 50E-CC
CC-Link Slave
cifx-ccs_1.csp, cifx-ccs_2.csp, cifx-ccs_3.csp, cifx-ccs_4.csp,
(for one, two, three or four Remote Device Station),
cifx-ccs_io.csp (for one Remote IO Device Station)
Table 8: Device Description Files for PC Cards cifX