Page | 59
Signal Alarms
Enter
: for No
Enter
: for Yes
Press the
key.
Repeat for Signal Faults, Signal
Open/Close and Signal Access C.
Press the
key. ‘Program PCs’
will be displayed. Repeat for
further PCs or press the
key.
If required, enter a text password,
this protects the EURO 280
system from anyone dialling in.
This password must be entered at
the Insite software in order for the
PC to connect to the panel. Press
the
key.
Select the number of redials which
the panel will attempt (0-15).
Press the
key. Repeat for the
Time Out (The time that the panel
will wait for a reply). Press the
key. The options: Time Out
and Dial Mode are not currently
supported please ignore these.
Press the
key. You will be
returned to the engineer menu.
Program ARC?
The EURO 280 system fitted with digi-modem can be used to dial to an Alarm Receiving Centre
or send SMS texts to a mobile phone.
4.1.62 Programming Fast Format
The Fast Format type 4.8.1 is commonly used for BSIA Fast Format. Up to four numbers can
be programmed, each with individual account numbers, channel information and back up
telephone number option. The channels can be individually programmed in the “Program Digi
Channels” section. Each channel uses a programmable output number. The default values are
described on below:
Digi Channel
Output Types
1
Fire (0001)
2
HU Device Any (0009)
3
Unconfirmed Any (0018)
4
Final Set Any (0022)
5
Confirmed Any (0006)
6
Misoperation (0005)
7
Omit Rearm Any (0017)
8
Mains Fail (0052)
9
Global Fault 2 (0056)
10
Test ATS (0064)
The communicator “status channel” (channel 0) is used for low voltage and test calls.