Page | 43
User Outputs?
Use this menu to program the type
(Latched or Timed), time in seconds
(if Timed), and name of User
Outputs. Use this menu in
conjunction with programming of
keyfob buttons and user defined
output types to setup custom User
Outputs
Press the
key
You will be returned to the Engineer
Menu.
4.1.45 The ‘Follow Input’ Output
This output provides the following functionality:
Follow (whilst input active), TIMED, LATCHED output or CODE RESET
Follow individual INPUT, AREA, WARD or SHUNT LIST
Follow WHEN SET, WHEN UNSET or ALWAYS
NOTE: The Follow Input type WILL NOT function correctly if assigned to ATE pins.
Change Outputs
Using the
and
keys, scroll
to
‘CHANGE OUTPUTS?
’
Press the
key
Endstation Output
To program the control panel
Output and the STU/ATE pins press
the
key.
Select the output you desire, and
select the output type as ‘0035’ =
Follow Input.
Press the
key.
Follow Type?
Enter
: for
Follow
(Default)
Enter
: for
Timed
(You will need to enter the time you
would like the output to be
activated for - in seconds)
Enter
for
Latched.
Enter
for
Code Reset.
Press the
key.