Page | 25
4.1.19 Access Control/Door Entry Control
The following programming shows how to set up the Access Control facility if you are using it.
The same programming process applies to ‘Door Entry Control’ which allows a tag reader to
control an entry point.
Assign Keypads/Readers
Using the
and
keys, scroll to
‘ASSIGN KEYPADS/READERS?
’
Press the
key
Address
Enter the address of the
keypad/reader you wish to assign.
Press the
key
NOTE: Address 00 is Keypad
ONLY
Type
Enter
: for
Reader.
Press the
key
Reader Is
Enter
: for
Access Control
Or
Enter
: for
Entry Control
Press the
key
Enter the Lock Open Time (max: 255
seconds). This is the time the door
release is going to be active when a
valid tag is presented. Press the
key.
Enter the Door Open Time (max: 255
seconds). This is the time the door is
allowed to be open before triggering
an alarm. Press the
key.
Enter the input number to monitor
the chosen door. Please note that this
must be selected for the door
monitoring to function.
Entering ‘999’ disables the
monitoring for this door.