Page | 45
Site Options
A full range of site options is available to tailor the operation of the system.
4.1.46 Site Option Types
Option
Default
Function
Set With Fault
Yes
If ‘
YES’
: Allows setting with the following faults active: Device fail,
Mains fail, Battery faults, Fuse faults, SMS failure, relay sirens 1&2,
relay Strobe faults.
Set With
Tamper
No
If ‘
YES’
: Allows setting with the following faults active: Case tamper
and System tampers.
Set With ATS
Fault
No
If ‘
YES’
: Allows setting with the following faults active: Telecom line
fail, Modem failed, STU/ATE line fault, STU/ATE one path fail, Digi dial
fail, STU/ATE comms fail.
Set With Ward
Fault
Yes
If ‘
YES’
: Allows a ward to be set if mains, battery, telecom line, or
other system fault is present.
Set Fail =
Alarm
No
If ‘
YES’
= A graduated alarm will be generated when ‘Set Fail’ timer
expires (see Change Timers), if exit procedure is still incomplete. Set
fail output will trigger.
If ‘
NO’
= Exit time will continue until the Exit route is clear.
Do Bat Load
Test
No
If ‘
YES’
: Programmes the system to perform a full load test of the
battery at 7.00am each day.
Ward
Misoperate
No
If ‘
YES’
Allows a Misoperation (Abort) signal to be generated without
the entry of a valid code into the system when a ward is operated
after an alarm.
Strobe/Squawk
at set
None
If ‘
STROBE’
: A ‘STROBE ANY’ output will be activated for 5 seconds
as the system arms. If ‘
SQUAWK’
: A ‘SIREN ANY’ output will be
activated for 5 seconds as the system arms. If ‘
BOTH
’ then both of
the above will activate for 5 seconds as the system arms.
Use with
care, in view of potential security risk.
Re-Arm Omits
No
If ‘
YES’
: At rearm at the end of the confirmation time, this function
will force an input (not a system tamper) causing an unconfirmed
alarm to be omitted, whether it’s still in fault or not.
Use Level Set
No
If ‘
YES’
: The system becomes a ‘level set’ (Having one area set only
at any one time, e.g. part sets). If ‘
NO’
: The system becomes a ‘area’
system (setting more than once area at a time)
Confirmed
When
Final
Set
Final Set
: Confirmed signal only available after the system is set.
Exit Starts:
Confirmed signal available after the exit time has
started.
NOTE: Not compliant with BS8243.
Note: ‘Exit Starts’ must be
selected in order for it to be entered in the logs.
AutoSet Force
No
If ‘
YES’
when autoset is in use (this is only available in the InSite
software) the panel will still set even if an input is open at the time.
This also applies for setting with key fobs.
Restrict PIN
Use
No
If ‘
YES’
the system prevents a pin code being accepted on the Entry
Time, but allows the system to be silenced and unset once in alarm.
Enable when BS8243 option 6.4.5 is in use.
Simple Set
No
Enables the ‘simple set’ functionality which allows a user to set the
system by pressing the ‘YES’ key and the level set.
PLEASE NOTE THIS FEATURE IS NOT UK COMPLIANT
Invert ATE
O/Ps
Yes
If ‘
YES’
: ‘Positive Removed’ If ‘
NO’
: ‘Positive Applied’
Common Lobby
Yes
If set to ‘
YES’
, this will automatically select the ‘highest’ exit mode
for all partitions. (0 = Timed, 1 = Final Door, 2 = Timed/Final Door, 3
= PTS). For example, if Area C is selected as Final Door and the rest
of the partitions are selected as Timed, then because Final Door is
‘higher’ than Timed (Final door is 1 and Timed is 0), all partitions will
be set to Final Door. If set to ‘
NO’
the Exit Modes will be individually
programmable to each area.
Flexi Unset
No
If set to ‘
YES’
, this will allow all codes with Flexi-Set attribute
enabled to choose which partitions to set/unset during entry time.
This option should always be selected when BS8243 option 6.4.5 is in
use
2 Key HU
None
2 Key Hold Up Alarm at the keypad. The
and
keys, are
pressed simultaneously to produce a hold up. This also acticates the
HU on the remote 4 button key fobs.