Page | 32
Exit Modes
Using the
and
keys, scroll to
‘EXIT MODES?
’
Press the
key
Area Exit Modes
Enter
: for
Timed.
Enter
: for
Final Door
Enter
: for
Timed/Final
Enter
: for
Push To Set
Press the
key. Repeat for each
Area or press the
key to return to
the Engineer Menu.
Change Codes (Duress/Guard Only)
All codes may be 4, 5, or 6 digit or proximity tags. Using a 5 or 6 digit code will automatically
block several possible 4 digit codes that clash with it. Please note that the EURO System will
only comply with Grade 3 if you have “5 digit codes” enabled.
NOTES: Only Duress, Master
Manager and Guard codes can be changed by the Engineer, Normal user codes and
keyfobs can only be changed in the Manager User Menus. The Master Manager and
Engineer Codes cannot be deleted.
4.1.29 Code Types and Numbers.
Alarm System
User/Manager Codes
Wireless Keyfobs
Duress/Guard Codes
EURO 280
500
32
20
4.1.30 Wireless Keyfobs
Wireless keyfobs can only be programmed from the Master Manager Menu, and can only be
learnt to the system if a wireless ZEM is installed.
4.1.31 Code Types
User Type
Functions
Operation
User
Default: 1234
Set and Unset System. Also for Access Control
and Sub Area Control functions
Programmed by
Manager only.
Manager
Set and Unset System
Also access to Manager menu functions
Programmed by
Manager only.
Master Manager
Default: 2222
Set and Unset System.
Also access to Manager menu functions
Programmed by
Manager or
Engineer.
Engineer
Default: 1111
Access to all engineering functions; also
Set/Unset system for test purposes.
Programmed by
Engineer.
Duress
Unsetting system generates silent ‘Duress’ or
‘Hold Up’ signal.
NOTE: May be permitted at Grade 3 only with
police approval
Programmed by
Engineer.
Guard
Unset system, but only after an alarm has been
active for a minimum time (programmable). Also
Set system. An output type is available to signal
whenever this code is used.
Programmed by
Engineer.