Page | 31
Set Time and Date
All log entries and the system display include the time and date. This may be also programmed
in the Master Manager Mode.
NOTE: Please note that powering down the system will
reset the time and date information.
Set Date and Time
Using the
and
keys, scroll to
‘SET DATE AND TIME?
’
Press the
key
Year
Adjust the year as required using the
numeric keys. Press the
key.
Repeat for Month, Day and Hours.
Press the
key. You will be returned
to the engineer menu.
Daylight Saving Time Adjust
Enter
: for
No
Enter
: for
Yes
Press the
key
This automatically adjusts the time for
summer/winter
Exit Modes
The ‘
Exit Modes
’ operate the Setting procedure of the EURO system. The following Exit Modes
are available:
4.1.25 Timed
The EURO system will only set when the programmed Exit Time has expired (See ‘Change
Timers’ page 29) providing that all inputs are closed.
(Default setting for all areas/level
sets). NOTE: This is NOT suitable for systems installed to comply with BS8243.
4.1.26 Final Door
The EURO system will only set when an input programmed as Final Exit is either closed (if the
input was opened when setting started) or opened then closed (if the input was closed). This
mode may also be used for
‘lock set’
operation: securing the lock completes the Setting
procedure, unlocking starts the entry time.
4.1.27 Timed/Final
This function follows ‘timed’ operation, except that the timer will be overridden if an Final Exit
input is opened and closed before the timer expires (See above: Final Door).
NOTE: This is NOT suitable for systems installed to comply with BS8243.
4.1.28 PTS (Push To Set)
PTS = Push to Set. The EURO system will only set when a ‘Push to Set’ button has been
pressed.