Page | 21
Chime
Enter
: for
No.
(Default)
Enter
: for
Single.
Enter
: for
Follow.
Press the
key
Omittable
Enter
: for
No.
(Default)
Enter
: for
Yes.
Press the
key. Repeat for Double
Knock, Dual Trip, Normally Open,
Walk Test, Monitor Activity; until
Special Log:
Special Log
Enter
: for
No.
(Default)
Enter
: for
Set.
Enter
: for
Unset.
Enter
: for
Always.
Press the
key.
Confirm Group
Enter the Confirm Group if used.
Press the
key
Input Description and Location
If you would like to enter a
description for the input, press the
key. After entering a description
press
to enter a location Text
programming is described on page:
7. Press the
key when finished,
NOTE: Repeat all the above for further inputs, or press the
key to return to the
Engineers Menu.
After programming the inputs, it is necessary to exit the Engineer Menu for the
programming to take effect, before the inputs are walk tested, etc.
4.1.14 Shunt Inputs
A shunt group may consist of any number of inputs programmed as Intruder, Tamper, Day
Alarm and Entry Route types. These must all be allocated in the same Area.
NOTE: These will
need to be programmed first.
The inputs in the shunt group/list will only activate after 10 seconds of the nominated shunt
input. For example, if input 1 is programmed as ‘Shunt Input’, and inputs 2 and 3 are
programmed as “Day Alarm”, then once input 1 has been opened, after 10 seconds inputs 2
and 3 become active. (Inputs 2 and 3 will not become live after 10 seconds if either detector is
in alarm condition).