4.1.12 Masking Response
When unset, a masking event will generate an audible “alert” that requires response in the
normal way. There will be NO signal transmitted to the ARC. When set, a masking event will
generate an ‘intrusion’ response including “intruder” or “unconfirmed” output, but will NOT
result in a confirmed alarm if paired with a activation of the same detector. This harmonises
with the requirement of EN50131-1 clause 8.4.5 and the insurer’s preference expressed in
BSIA Form 171.
4.1.13 Input Programming
Change Inputs
Using the
and
keys, scroll to
‘
CHANGE INPUTS?
’. Press the
key
Input
Select the input number you wish to
program and press
the
key.
Input Type
Select the input type (See the ‘input
types’ table – Page: 17) by using
either the numeric code or the
and
keys.
Press the
key.
Input Areas
Enter the areas/level sets you would
like the input to be active in (To
select level setting instead of areas
please refer to Site Options “Use
Level Set”, see page: 45).
NOTE: The
primary Areas are A, B, C and D.
Press the
key.
Input Areas
For area setting systems only:
Enter
: for
Any
(Default)
Enter
: for
All
Press the
key
Input Attributes
Press the
key to select any
attributes for the input (for details on
each attribute see page: 19)