Page | 57
Set Up Downloading
The EURO 280 system has uploading and downloading capability. The UDL Software allows you
to monitor the status of each input, alter programming, and review the logs. There are three
ways that the panel communicates with the PC, one is remotely; via the telephone line,(thus
requiring a DIGI modem card) then there is direct connection; by using a USB lead – and in
future there will be a modem slot adapter to allow RS-232 connection to WebWayOne and
Chiron services.
4.1.58 Download By
Select:
[1]
Modem,
[2]
RS-232
(future use)
[4]
WebWayOne
(future use via RS-232 adapter)
,
[5]
Chiron
(future use via RS-232 adapter)
[8]
USB
(direct cable connection)
4.1.59 Security Mode
This function allows you to choose a range of dialling modes that can be used:
Security Mode: To comply with DD263:2010:
This function is now defaulted to ‘Dial Back’.
When creating a customer in InSite, it is important that the control panel site telephone
number is programmed. It is also important that the InSite modem telephone number is
programmed in PC1 of the downloading menu at the control panel. When dialling a control
panel click the Dial Customer option in InSite and the PC will call the control panel, once the
control panel has answered, the panel and InSite will hang up. After a few seconds the control
panel will call the PC modem and InSite, from here an upload or download may take place.
Auto Answer:
permits the PC to dial into the panel.
Panel Dials:
does not allow the PC to dial into the panel at all. All modes allow the panel to
dial the PC without restriction. At any time, the panel can be forced to dial the PC by entering
the Manager menu and selecting the Dial Out Menu. Please see page 67.
Roving Dial:
This option (when disabled) prevents anyone dialling into the panel using roving
dial from the InSite software. It is possible to do a roving dial to a control panel, when the
control panel is in its default state. To comply with DD263:2010 this option must be defaulted
to disabled.
4.1.60 Telephone Line
Dedicated Line:
When the PC dials the panel, it will respond immediately.
Shared Line:
When the PC dials the panel, it will hang up after a number of rings, and dial
again. The first call primes the panel, which will then answer the second call.
4.1.61 ARM / Modem Telephone Number
To be used in conjunction with the
‘DIAL OUT MENU’
function (see page: 67), these are
programmed for the appropriate PC.
Set up Downloading
Using the
and
keys, scroll
to
‘SET UP DOWNLOADING?
’
Press the
key
Download By
: None.
: Modem
: RS232.
: WebWayOne
: Chiron
: USB
Then press the