PCL 600
Operators Manual
v 2.0
63
Error number
Error text
Problem/Reference chapter
Profiling
014:008:011
Cutting cell doors opened, close doors before
proceeding.
Close the doors and try again.
014:008:013
Material too short for selected file. Not all positions
may be cut
The raw bar is too short to contain
all the parts in the cutting file. Use a
longer bar or a different data file.
014:008:025
Plasma unit not ready.
Turn on the plasma unit. Wait until it
is ready before continuing.
014:008:026
Robot spline not running while cutting.
Make a note of the error and events
leading up to it and call HGG.
014:008:101
Error calculating macros. File: <named file>.
014:008:105
Calculator returned no profiles.
014:008:701
Timeout gearing axes for profiling.
It has taken too long to synchronise
these axes, check the amplifiers.
Material handling
014:016:009
Track Calibrate timeout.
The gripper track calibration has
taken too long. Is ‘Slow’ handling
activated? Turn it off. Check if the
gripper home switch is still working.
014:016:011
Track Calibrate home error.
Check if the gripper home switch is
still working.
014:016:028
Pusher in synchro. mode no action allowed.
You cannot perform a ‘home’ action
when the gripper is still geared.
Ungear the gripper.
014:016:037
Track Calibrate error, end switch not reached.
Check if the gripper home switch is
still working. Check that the gripper
can move freely to the end.
014:016:038
Detection cylinder front position timeout
Check if the material detection
mechanism on the front of the
gripper is moving freely.
014:016:039
Gripper open timeout.
It has taken too long to open the
gripper. Make sure the gripper is not
stuck and can move freely, try
again.
014:016:040
Error. Detection cylinder not in front position for
home.
Check if the material detection
mechanism on the front of the
gripper is moving freely.
014:016:042
Error pushing material to cabin.
Check if the infeed track sensor is
still working.
014:016:043
Error pushing material to cabin. Material too short.
The profile is too short to contain all
the parts. Load a longer bar or a
cutting file that does fit into this bar.
014:016:044
Error moving to zero pos., end switch not reached.
Turn off ‘Slow’ material handling if it
is activated. Check if the gripper
home switch is still working. Try
again.
014:016:046
Track move to zero pos. timeout.
014:016:048
Error opening gripper.
Make sure the gripper is not stuck
and can move freely, try again.