PCL 600
Operators Manual
v 2.0
14
2.6 Emergency
stop
Pressing the ‘Emergency stop’ button located on the remote control will stop all machine
activity. It is possible that some machine components may decelerate to a stop without this
movement being recorded by the CNC controller. Therefore it is important to check the
alignment of the torch position if the
emergency stop is pressed during profiling.
This can be done using the ‘Reverse’ button to move back in
the cut (see chapter 6.5: Cutting sequence for more
information). There is also an emergency stop for the robot
and on the manual control pendant (for more information see
the Robot Control Manual). The shock sensor on the cutting
torch will also trigger an emergency stop if the torch collides
with material. When the emergency stop is pressed, the
following window will appear on the touch screen of the
remote control:
The following procedure must be followed to restart the machine after an emergency stop:
1
MAKE SURE THAT IT IS SAFE TO OPERATE THE MACHINE AGAIN!
2
Pull out the emergency stop button on the remote control.
3
Press (or click on) the ‘Emergency stop restart’ window on the remote control.
4
Activate the robot ‘High power’ by pressing the button on the left side of the remote
control touch screen.
The machine is now ready to continue profiling. It may be necessary to home the machine components
before continuing. Follow the steps below.
5
Open the ‘Calibration’ screen by pressing the button at the bottom of the remote
control touch screen.
6
Remove the safety lock and home the sideways infeed chains by pressing the
button in the ‘Calibration’ section of the touch screen.
7
Home the gripper by pressing the button in the ‘Calibration’ section of the touch
screen.
8
Home the clamping bars in the cutting cell.
9
Home the printer.
10
Check that the machine is ready. The red ‘cross’ button on the top left of the screen
is replaced by the green ‘tick’ button.